TAS I8D4 Dispensary
TAS Part I8 Pharmacies
(1) A dispensary must be located—
within a pharmacy in a position to enable a person in the dispensary to supervise the dispensary, storage areas for narcotic substances and poisons, the entrances to unpacking areas and areas for storing other substances, and the retail area; and
separate from any place where goods are unpacked or where general merchandise, not used in dispensing, is stored.
(2) Each dispensary must be provided with—
a sink and drainage board of impervious material moulded or manufactured in one piece; and
a reticulated supply of hot and cold water capable of providing to the sink adequate quantities of water for dispensing purposes; and
space for a dispensing bench with a working area not less than 1.4 m2.
Changed in NCC 2025. See NCC 2025 Volume One TAS I8D4, or show what changed.
Delete clause I8D4 and insert TAS I8D4 as follows: (1) A dispensary must be located — within a pharmacy … bench with a working area not less than 1.4 m2.
Removed words are struck through; added words are highlighted. Comparison of the text only.