Western Australia variation · NCC 2022 Volume One

WA B2D1 Regional wind speeds

WA Part B2 Changes to AS/NZS 1170.2:2021

Open on NCC Online ↗

Delete Table 3.1(A) of AS/NZS 1170.2:2021 and replace with WA Table B2D1.

Insert WA table (B2D1) B2D1 as follows:

WA Table B2D1: Table 3.1(A)—Regional wind speeds—Australia

Regional wind speed

Region

Non-cyclonic

Cyclonic

A (0-5)

B1

B2

C (maximum)

D (maximum)

V1

30

26

23

23

V5

32

28

33

35

V10

34

33

39

43

V20

37

38

45

51

V25

37

39

47

53

V50

39

44

52

60

V100

41

48

56

66

V200

43

52

61

72

V250

43

53

62

74

V500

45

57

66

80

V1000

46

60

70

85

V2000

48

63

73

90

V2500

48

64

74

91

V5000

50

67

78

95

V10000

51

69

81

99

VR (R ≥ 5 years)

67-41R-0.1

106-92R-0.1

122-104R-0.1

156-142R-0.1

Table Notes

The peak gust has an equivalent moving average time of approximately 0.2 s (Holmes and Ginger, 2012).

Values for V1 have not been calculated by the formular for VR in the Australian regions.

For ultimate or serviceability limit states, refer to the National Construction Code (Australia) or AS/NZS 1170.0 for information on values of importance level and annual probability of exceedance appropriate for the design of structures. For buildings in townships in cyclonic regions, users should consider overall risk to a community when selecting importance levels.

For Regions C and D, only the maximum values for the region are tabulated. Lower values of VR may apply in those regions, depending on the distance of the site from the smooth coastline.

Not in NCC 2025. No WA B2D1 in NCC 2025 Volume One.