NCC 2022 Volume One
Western Australia variations
13 WA variations to NCC 2022 Volume One: clauses replaced, added or deleted in Western Australia. Search with WA variations.
- WA B1D3 Determination of individual actionsDelete clause B1D3 and insert WA B1D3 as follows: The magnitude of individual actions must be determined in accordance with the following: Permanent…
- WA B1D4 Determination of structural resistance of materials and forms of constructionDelete clause B1D4 and insert WA B1D4 as follows: The structural resistance of materials and forms of construction must be determined in accordance…
- WA B2D1 Regional wind speedsDelete Table 3.1(A) of AS/NZS 1170.2:2021 and replace with WA Table B2D1. Insert WA table (B2D1) B2D1 as follows: WA Table B2D1: Table…
- WA B2D2 Internal pressureDelete 5.3.1 of AS/NZS 1170.2:2021 and replace with the following: 5.3.1 Internal pressure 5.3.1.1 General Internal pressure is a function of the…
- WA B2D3 OpeningsDelete 5.3.2 of AS/NZS 1170.2:2021 and replace with the following: 5.3.2 Openings 5.3.2.1 General Openings shall be determined according to either…
- WA I4D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1, D1P2, D1P3, D1P4, D1P6 and F6P2 are satisfied by complying with— Part…
- WA I4D2 Application of PartThe Deemed-to-Satisfy Provisions of this Part apply to a WA public building or part of a building.
- WA I4D3 Additional exitsIn a WA public buildings, each storey that accommodates more than 50 persons must have more than one exit from that storey.
- WA I4D4 Goings and risersSteps serving a WA public building must have risers not more than 180 mm and goings not less than 280 mm. (2) The requirements of (1) do not apply…
- WA I4D5 Handrails to ramps, flights and landingsFor a WA public building, handrails must be located along— both sides of a ramp or flight; and each side of a landing, except for that part of a…
- WA I4D6 Artificial lightingArtificial lighting must be provided along the external path of travel (including steps, landings, ramps or paths) to a road or open space…
- WA I4D7 Fixed seatingWhere fixed seating in a Class 9b WA public building is arranged in more than one row— aisles must be provided on both sides of every row that…
- WA S4C1 ScopeDelete subclause S4C1(2) and insert WA S4C1(2) as follows: (2) For the purposes of Specification 4, cyclonic areas are those determined as being…