NCC 2022 Volume Three
Part B7 Rainwater storage
9 clauses · Open on NCC Online ↗
- B7O1 ObjectiveThe Objective of this Part is to— safeguard people from illness, injury or loss (including loss of amenity) due to the failure of a rainwater…
- B7F1 Rainwater storageRainwater storage systems must be designed and installed so as to operate in a way that avoids the likelihood of inadvertent contamination of any…
- B7P1 Contamination control VICStored rainwater must reduce the likelihood of contamination. (2) Stored rainwater must not pose a hazard to public health.
- B7P2 Uncontrolled dischargeRainwater storage must avoid the likelihood of failure or uncontrolled discharge.
- B7P3 Access and isolationRainwater storage must allow access for cleaning and maintenance. (2) Rainwater storage must allow for the system to be isolated.
- B7P4 Identification VICRainwater storage and holding tanks used only for non-drinking purposes must be clearly identified. Exemptions Where rainwater storage is intended…
- B7D1 Deemed-to-Satisfy Provisions VICWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements B7P1 and B7P4 are satisfied by complying with B7D2 and B7D3. (2) Where a…
- B7D2 Collection of rainwater TASRainwater storage must only collect roof water.