Deemed-to-Satisfy Provision · NCC 2022 Volume Two

H1D11 Attachment of framed decks and balconies to external walls of buildings using a waling plate

Part H1 Structure · NCC 2019: 3.10.6.1

Open H1D11 on NCC Online ↗

Performance RequirementH1P1 is satisfied for the attachment of a deck or balcony to an external wall if it complies with Part 12.3 of the ABCB Housing Provisions, provided—

the deck or balcony is not located in an alpine area; and

the height of the deck or balcony is not more than 3 m measured from the uppermost finished floor surface of the deck or balcony at any point to the top of any supporting footing; and

the waling plate does not support—

more than one floor; or

loadbearing or non-loadbearing walls; or

roof loads; and

the deck or balcony does not cantilever off the external wall; and

the total imposed load on the deck or balcony does not exceed 2 kPa; and

the deck or balcony framing including member sizes, spans and spacing, bracing for racking and shear forces, fixings and structural supports complies with H1D2; and

steel framing constructed in accordance with H1D6(3); and

timber framing is constructed in accordance with H1D6(4); and

the external wall supporting the deck or balcony is constructed of—

190 mm thick fully core-filled concrete masonry, reinforced with vertical N12 bars at not more than 600 mm centres; or

steel framing complying with H1D6(3); or

timber framing complying with H1D6(4); and

the external wall referred to in (i) must be continuous from the upper most surface of the deck or balcony to the supporting footing and contain no openings or lintels below the deck or balcony; and

the waling plate is fixed to the external wall in accordance with clause 12.3.2 of the ABCB Housing Provisions and attached by—

fixing the waling plate through wall cladding complying with H1D7(4) or H1D7(5), provided the cladding is directly fixed to the external wall; or

removing parts of the wall cladding so that the waling plate is directly fixed to the external wall, with—

the junction of the waling plate and the external wall flashed in accordance with clause 12.3.3 of the ABCB Housing Provisions; and

the cladding restored to its original strength by installing blocking supports as necessary on completion of installation; and

the deck or balcony is braced to prevent lateral movement in accordance with clause 12.3.4 of the ABCB Housing Provisions.

Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two H1D11.

Clauses referred to

Defined terms used