Performance Requirement · NCC 2022 Volume Two

H1P1 Structural reliability and resistance

Part H1 Structure · NCC 2019: P2.1.1

Open H1P1 on NCC Online ↗

(1) By resisting the actions to which it may reasonably be expected to be subjected, a building or structure, during construction and use, with appropriate degrees of reliability, must—

perform adequately under all reasonably expected design actions; and

withstand extreme or frequently repeated design actions; and

be designed to sustain local damage, with the structural system as a remaining stable and not being damaged to an extent disproportionate to the original local damage; and

avoid causing damage to other properties.

(2) The actions to be considered to satisfy (1) include but are not limited to—

permanent actions (dead loads); and

imposed actions (live loads arising from occupancy and use); and

wind action; and

earthquake action; and

snow action; and

liquid pressure action; and

ground water action; and

rainwater action (including ponding action); and

earth pressure action; and

differential movement; and

time dependent effects (including creep and shrinkage); and

thermal effects; and

ground movement caused by—

swelling, shrinkage or freezing of the subsoil; and

landslip or subsidence; and

siteworks associated with the building or structure; and

construction activity actions; and

termite actions.

(3) The structural resistance of materials and forms of construction must be determined using five percentile characteristic material properties with appropriate allowance for—

known construction activities; and

type of material; and

characteristics of the site; and

the degree of accuracy inherent in the methods used to assess the structural behaviour; and

action effects arising from the differential settlement of foundations, and from restrained dimensional changes due to temperature, moisture, shrinkage, creep and similar effects.

(4) Glass installations that are at risk of being subjected to human impact must have glazing that—

if broken on impact, will break in a way that is not likely to cause injury to people; and

resists a reasonably foreseeable human impact without breaking; and

is protected or marked in a way that will reduce the likelihood of human impact.

Changed in NCC 2025. See NCC 2025 Volume Two H1P1, or show what changed.

(1) By resisting the actions to which it may reasonably … a building or structure, during construction and use, with appropriate degrees levels of reliability, must — perform adequately under all reasonably expected … local damage; and avoid causing damage to other properties. (2) Each component of the building or structure must withstand all actions with the minimum levels of reliability specified in Tables H1P1a, H1P1b and H1P1c as determined in accordance with H1V1. (3) The actions to be considered to satisfy (1) and (2) include but are not limited to — permanent actions (dead … building or structure; and construction activity actions; and termite actions. (3) (4) The structural resistance of materials and forms of construction must be determined using five percentile characteristic material properties with appropriate allowance for — known construction activities; type and type of material; and characteristics use of the site; material and the degree of accuracy inherent in the methods used to assess the structural behaviour; and action effects arising from the differential settlement of foundations, and from restrained dimensional changes due to temperature, moisture, shrinkage, creep and similar effects. (4) behaviour. (5) Glass installations that are at risk of being subjected to … a way that will reduce the likelihood of human impact. Table H1P1a Minimum annual reliability indices (β) for additive load combinations (gravity actions only) All Importance Levels [formula] = 4.30 Table Notes The annual reliability indices in Table H1P1a must be met for all components necessary to comply with H1P1(1) at the relevant Importance Level. Ancillary components may have a reliability index appropriate to the component, but not less than that required for Importance Level 1, irrespective of the Importance Level of the whole building or structure. Importance Level must be assigned in accordance with Table 2.2.3a of the ABCB Housing Provisions. Table H1P1b Minimum annual reliability indices (β) for additive load combinations (combined gravity and other actions) Importance Level 1 Importance Level 2 [formula] = 3.45 [formula] = 3.70 Table Notes The annual reliability indices in Table H1P1b must be met for all component necessary to comply with H1P1(1) at the relevant Importance Level. Ancillary components may have a reliability index appropriate to the component, but not less than that required for Importance Level 1, irrespective of the Importance Level of the whole building or structure. Importance Level must be assigned in accordance with Table 2.2.3a of the ABCB Housing Provisions. Table H1P1c Minimum annual reliability indices (β) for action reversal and stability load combinations (combined gravity and other actions) Importance of Level 1 Importance Level 2 [formula] = 3.00 [formula] = 3.35 Table Notes The annual reliability indices in Table H1P1c must be met for all components necessary to comply with H1P1(1) at the relevant Importance Level. Ancillary components may have a reliability index appropriate to the component, but not less than that required for Importance Level 1, irrespective of the Importance Level of the whole building or structure. Importance Level must be assigned in accordance with Table 2.2.3a of the ABCB Housing Provisions. Notes H1P1(2) does not take effect until 1 year after the adoption date for NCC 2025. When assessing compliance with H1P1(3)(a) to (e), the actions must include those derived from the relevant part of the AS/NZS 1170 series of standards.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used