Deemed-to-Satisfy Provision · NCC 2022 Volume Two
H2D4 Masonry
Part H2 Damp and weatherproofing · NCC 2019: 3.3.4
Varied in SA. Check the variation for your state.
(1) H2D4(2)—
applies to every external wall (including the junction between the wall and any window or door) of a Class 1 building; and
does not apply to any Class 10 building except where its construction contributes to the weatherproofing of the Class 1 building.
(2) Performance RequirementsH2P2 and H2P3 are satisfied for weatherproofing of masonry if it is carried out in accordance with the appropriate provisions of one of the following:
AS 3700.
AS 4773.1 and AS 4773.2.
Part 5.7 of the ABCB Housing Provisions provided masonry walls are constructed in accordance with H1D5 and the requirements of Part 5.7.
Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two H2D4.