Performance Requirement · NCC 2022 Volume Two

H2P1 Rainwater management

Part H2 Damp and weatherproofing · NCC 2019: P2.2.1

Open H2P1 on NCC Online ↗

(1) Surface water, resulting from a storm having an annual exceedance probability of 5% and which is collected or concentrated by a building or sitework, must be disposed of in a way that avoids the likelihood of damage or nuisance to any other property.

(2) Surface water, resulting from a storm having an annual exceedance probability of 1% must not enter the building.

(3) A drainage system for the disposal of surface water resulting from a storm having an annual exceedance probability of—

5% must—

convey surface water to an appropriate outfall; and

avoid surface water damaging the building; and

1% must avoid the entry of surface water into a building.

Limitations

H2P1(2) does not apply to a Class 10 building except where its construction contributes to the weatherproofing of the Class 1 building.

Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two H2P1.

Defined terms used