H3P1 Spread of fire
Part H3 Fire safety · NCC 2019: P2.3.1
(1) A Class 1 building must be protected from the spread of fire such that the probability of a building not being able to withstand the design heat flux of 92.6 kW/m² for a period of 60 minutes shall not exceed 0.01, when located within 900 mm from the allotment boundary or within 1.8 m from another building on the same allotment from—
another building other than an associated Class 10 building; and
the allotment boundary, other than a boundary adjoining a road or public space (see Figure H3P1).
(2) A Class 10a building must not significantly increase the risk of fire spread between Class 2 to 9 buildings.
Figure H3P1 Typical areas of potential fire spread
Figure Notes
This diagram indicates areas of potential fire spread. This situation will differ for corner allotments, etc.