Performance Requirement · NCC 2022 Volume Two
H7P4 Buildings in alpine areas
Part H7 Ancillary provisions and additional construction requirements · NCC 2019: 2.7.4
(1) An external doorway from a building in an alpine area must be installed so that opening the door is not obstructed by snow or ice.
(2) A building in an alpine area containing external trafficable structures forming part of the means of egress must be constructed so that they remain, as far as practicable, useable under snow conditions.
(3) A building in an alpine area must be constructed so that snow or ice is not shed from the building onto the allotment, any adjoining allotment, road or public space in a location or manner that will—
obstruct a means of egress from any building to a road or open space; or
otherwise endanger people.
Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two H7P4.