H7P5 Buildings in bushfire prone areas
Part H7 Ancillary provisions and additional construction requirements · NCC 2019: TAS P2.7.5, P2.7.5
A Class 1 building or a Class 10a building or deck associated with a Class 1 building that is constructed in a designated bushfire prone area must be designed and constructed to—
reduce the risk of ignition from a design bushfire with an annual exceedance probability not more than 1:50 years; and
take account of the assessed duration and intensity of the fire actions of the design bushfire; and
be designed to prevent internal ignition of the building and its contents; and
maintain the structural integrity of the building for the duration of the design bushfire.