New South Wales variation · NCC 2022 Volume Two

NSW H6P2 Building sealing

NSW Part H6 Energy efficiency · varies H6P2 Energy usage

Open on NCC Online ↗

A building must have, to the degree necessary, a level of building sealing against air leakage to facilitate the efficient use of energy for artificial heating and cooling appropriate to—

the function and use of the building; and

the internal environment; and

the geographic location of the building.

Limitations

NSW H6P2 does not apply to—

existing buildings being relocated; or

Class 10a buildings—

without a conditioned space; or

for the accommodation of vehicles; or

parts of buildings that cannot be fully enclosed; or

a permanent building opening, in a space where a gas appliance is located, that is necessary for the safe operation of a gas appliance; or

a building in climate zones 2 and 5 where the only means of air-conditioning is by using an evaporative cooler.

Not in NCC 2025. No NSW H6P2 in NCC 2025 Volume Two.

The national clause