NCC 2022 Volume Two
Specification 2 Descriptions of elements referred to in Specification 1
29 clauses · Open on NCC Online ↗
- S2C1 ScopeThis Specification sets out the descriptions of elements referred to in Tables S1C2a, S1C2b, S1C2c, S1C2e, S1C2f, S1C2g, S1C2h, S1C2i, S1C2j, S1C2l…
- S2C2 Mortar for masonryMasonry units of ashlar, calcium silicate, concrete or fired clay (including terracotta blocks) must be laid in cement mortar or composition mortar…
- S2C3 Gypsum blocksGypsum blocks must be laid in gypsum-sand mortar or lime mortar.
- S2C4 Gypsum-sand mortar and plasterGypsum-sand mortar and gypsum-sand plaster must consist of either— not more than 3 parts by volume of sand to 1 part by volume of gypsum; or if lime…
- S2C5 Gypsum-perlite and gypsum-vermiculite plasterGypsum-perlite or gypsum-vermiculite plaster must be applied— in either one or 2 coats each in the proportions of 1 m3 of perlite or vermiculite to…
- S2C6 Plaster of cement and sand or cement, lime and sandPlaster prescribed in Tables S1C2c, S1C2e, S1C2f, S1C2g, S1C2h, S1C2i, S1C2j, S1C2l and S1C2m— must consist of cement and sand or cement, lime and…
- S2C7 Plaster reinforcementIf plaster used as fire protection on walls is more than 19 mm thick— it must be reinforced with expanded metal lath that— has a mass per unit area…
- S2C8 Ashlar stone masonryAshlar masonry must not be used in a part of the building containing more than 2 storeys, and must not be of— aplite, granite, granodiorite, quartz…
- S2C9 Dimensions of masonryThe thicknesses of masonry of calcium-silicate, concrete and fired clay are calculated as set out in S2C10 to S2C12.
- S2C10 Solid unitsFor masonry in which the amount of perforation or coring of the units does not exceed 25% by volume (based on the overall rectangular shape of the…
- S2C11 Hollow unitsFor masonry in which the amount of perforation or coring of the units exceeds 25% by volume (based on the overall rectangular shape of the unit) the…
- S2C12 Equivalent thicknessThe equivalent thickness of a masonry unit is calculated by dividing the net volume by the area of one vertical face.
- S2C13 Height-to-thickness ratio of certain wallsThe ratio of height between lateral supports to overall thickness of a wall of ashlar, no-fines concrete, unreinforced concrete, solid gypsum…
- S2C14 Increase in thickness by plastering — wallsIf a wall of ashlar, solid gypsum blocks or concrete is plastered on both sides to an equal thickness, the thickness of the wall for the purposes of…
- S2C15 Increase in thickness by plastering — columnsWhere Tables S1C2e, S1C2f, S1C2g, S1C2h, S1C2i and S1C2j indicate that column-protection is to be plastered, the tabulated thicknesses are those of…
- S2C16 Gypsum-perlite or gypsum-vermiculite plaster or metal lath — wallsIn walls fabricated of gypsum-perlite or gypsum-vermiculite plaster on metal lath and channel— the lath must be securely wired to each side of 19 mm…
- S2C17 Gypsum-perlite or gypsum-vermiculite plaster or metal lath — columnsFor the fire protection of steel columns with gypsum-perlite or gypsum-vermiculite on metal lath— the lath must be fixed at not more than 600 mm…
- S2C18 Gypsum-perlite or gypsum-vermiculite plaster or metal lath — beamsFor the fire protection of steel beams with gypsum-perlite or gypsum-vermiculite on metal lath— the lath must be fixed at not more than 600 mm…
- S2C19 Exposure of columnsA column incorporated in or in contact on one or more sides with a wall of solid masonry or concrete at least 100 mm thick may be considered to be…
- S2C20 Exposure of beamsA beam, open-web joist, girder or truss in direct and continuous contact with a concrete slab or a hollow block floor or roof may be considered to…
- S2C21 Filling of column spacesThe spaces between the fire-protective material and the steel (and any re-entrant parts of the column itself) must be filled solid with a…
- S2C22 Hollow terracotta blocksThe proportion of cored holes or perforations in a hollow terracotta block (based on the overall rectangular volume of the unit) must not exceed the…
- S2C23 Reinforcing for column and beam protection — masonryMasonry of calcium-silicate, fired clay and concrete for the protection of steel columns must have steel-wire or mesh reinforcement in every second…
- S2C24 Reinforcing for column and beam protection — gypsum blocks and hollow terracotta blocksGypsum blocks and hollow terracotta blocks for the protection of steel columns must have steel-wire or mesh reinforcement in every course and lapped…
- S2C25 Reinforcing for column and beam protection — structural concrete and poured gypsumIf a steel column or a steel beam is to be protected with structural concrete or poured gypsum, the concrete or gypsum must be reinforced with…
- Table S2C26a Reinforcement of gypsum-perlite or gypsum-vermiculite plaster sprayed to contour — vertical members with H or I cross-sectionSurface to be protected | Reinforcement required if smaller dimension of surface exceeds (mm) | Max spacing of fixings of the mesh to surface (mm)…
- Table S2C26b Reinforcement of gypsum-perlite or gypsum-vermiculite plaster sprayed to contour — vertical members with other shapesSurface to be protected | Reinforcement required if smaller dimensions of surface exceeds (mm) | Max spacing of fixings of the mesh to surface (mm)…
- S2C26 Reinforcing for column and beam protection — gypsum-perlite or gypsum-vermiculite plaster sprayed to contourIf a steel column or steel beam is protected with either gypsum-perlite or gypsum-vermiculite plaster sprayed to contour and the construction falls…
- S2C27 Measurement of thickness of column and beam protectionThe thickness of the fire protection to steel columns and steel beams (other than fire protection of gypsum-perlite or gypsum-vermiculite plaster…