Table · NCC 2022 Volume Two
Table H1D6b Effective load width for structural steel bearers and strutting beams—Continuous spanning rafter or joist
| Design Member | Member 1 | Member 2 | Member 3 |
|---|---|---|---|
| Effective load width | 0.4 x Span 1 | 0.6 x (Span 1 + Span 2) | 0.5 x (Span 2) + Span 3 |
Table Notes
The length of Span 3 must not be more than 0.5 x Span 2.
Table for H1D6 Framing
Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two Table H1D6b.