Table · NCC 2022 Volume Two

Table H2V1a Risk factors and scores

Part H2 Damp and weatherproofing

Open Table H2V1a on NCC Online ↗
Risk factorCategoryRisk severityScore
Wind regionRegion A(0-5) (AS/NZS 1170.2)Low to medium0
Region B1-2 (AS/NZS 1170.2)Low to medium0
Region C (AS/NZS 1170.2)High1
Region D (AS/NZS 1170.2)Very high2
Number of storeysOne storeyLow0
Two storeys in partMedium1
Two storeysHigh2
More than two storeysVery high4
Roof/wall junctionsRoof-to-wall junctions fully protectedLow0
Roof-to-wall junctions partially exposedMedium1
Roof-to-wall junctions fully exposedHigh3
Roof elements finishing within the boundaries formed by the external wallsVery high5
Eaves widthGreater than 600 mm for single storeyLow0
451-600 mm for single storeyMedium1
Greater than 600 mm for two storeyMedium1
101-450 mm for single storeyHigh2
451-600 mm for two storeyHigh2
Greater than 600 mm for above two storeyHigh2
0-100 mm for single storeyVery high5
0-450 mm for two storeyVery high5
Less than 600 mm for above two storeyVery high5
Envelope complexitySimple shape with single cladding typeLow0
Complex shape with no more than two cladding typesMedium1
Complex shape with more than two cladding typesHigh3
As for high risk but with fully exposed roof-to-wall junctionsVery high6
Decks, porches and balconiesNoneLow0
Timber slat deck or porch at ground levelLow0
Fully covered in plan view by roofMedium2
Timber slat deck attached at first or second floor levelMedium2
Balcony exposed in plan view at first floor levelHigh4
Balcony cantilevered at first floor levelHigh4
Balcony exposed in plan view at second floor level or aboveVery high6
Balcony cantilevered at second floor level or aboveVery high6

Table Notes

Eaves width is measured horizontally from the external face of any wall cladding to the outer edge of any overhang, including fascia and external gutters.

Barriers to prevent falling and parapets are considered as 0 mm eaves.

Table for H2V1 Weatherproofing

Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two Table H2V1a.