Table · NCC 2025 Volume Two
Table H2V1a Risk factors and scores
Part H2 Damp and weatherproofing
| Risk factor | Category | Risk severity | Score |
|---|---|---|---|
| Wind region | Region A(0-5) (AS/NZS 1170.2) | Low to medium | 0 |
| Region B1-2 (AS/NZS 1170.2) | Low to medium | 0 | |
| Region C (AS/NZS 1170.2) | High | 1 | |
| Region D (AS/NZS 1170.2) | Very high | 2 | |
| Number of storeys | One storey | Low | 0 |
| Two storeys in part | Medium | 1 | |
| Two storeys | High | 2 | |
| More than two storeys | Very high | 4 | |
| Roof/wall junctions | Roof-to-wall junctions fully protected | Low | 0 |
| Roof-to-wall junctions partially exposed | Medium | 1 | |
| Roof-to-wall junctions fully exposed | High | 3 | |
| Roof elements finishing within the boundaries formed by the external walls | Very high | 5 | |
| Eaves width | Greater than 600 mm for single storey | Low | 0 |
| 451-600 mm for single storey | Medium | 1 | |
| Greater than 600 mm for two storey | Medium | 1 | |
| 101-450 mm for single storey | High | 2 | |
| 451-600 mm for two storey | High | 2 | |
| Greater than 600 mm for above two storey | High | 2 | |
| 0-100 mm for single storey | Very high | 5 | |
| 0-450 mm for two storey | Very high | 5 | |
| Less than 600 mm for above two storey | Very high | 5 | |
| Envelope complexity | Simple shape with single cladding type | Low | 0 |
| Complex shape with no more than two cladding types | Medium | 1 | |
| Complex shape with more than two cladding types | High | 3 | |
| As for high risk but with fully exposed roof-to-wall junctions | Very high | 6 | |
| Decks, porches and balconies | None | Low | 0 |
| Timber slat deck or porch at ground level | Low | 0 | |
| Fully covered in plan view by roof | Medium | 2 | |
| Timber slat deck attached at first or second floor level | Medium | 2 | |
| Balcony exposed in plan view at first floor level | High | 4 | |
| Balcony cantilevered at first floor level | High | 4 | |
| Balcony exposed in plan view at second floor level or above | Very high | 6 | |
| Balcony cantilevered at second floor level or above | Very high | 6 |
Table Notes
Eaves width is measured horizontally from the external face of any wall cladding to the outer edge of any overhang, including fascia and external gutters.
Barriers to prevent falling and parapets are considered as 0 mm eaves.
Table for H2V1 Weatherproofing