Tasmania variation · NCC 2022 Volume Two

TAS H7P5 Buildings in bushfire prone areas

Part H7 Ancillary provisions and additional construction requirements · varies H7P5 Buildings in bushfire prone areas

Open on NCC Online ↗

Delete clause H7P5 and insert TAS H7P5 as follows:

A Class 1 building or a Class 10a building or deck associated with a Class 1 building that is constructed in a designated bushfire prone area must, to the degree necessary, be—

designed and constructed to reduce the risk of ignition from a bushfire, appropriate to the—

potential for ignition caused by burning embers, radiant heat or flame generated by a bushfire; and

intensity of the bushfire attack on the building; and

provided with vehicular access to the site to assist fire fighting and emergency personnel defend the building or evacuate occupants; and

provided with access at all times to a sufficient supply of water for fire fighting purposes on the site.

Notes

For additional requirements relating to bushfire prone areas, refer to the Director’s Determinations on Bushfire Hazard Areas – current versions available at www.cbos.tas.gov.au

Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two TAS H7P5.