Housing Provisions clause · ABCB Housing Provisions 2025

10.2.19 Preformed shower bases

Part 10.2 Wet area waterproofing

Open 10.2.19 on NCC Online ↗

Preformed shower bases must—

have an upturn lip (see Figure 10.2.19a and Figure 10 .2.19b); and

be recessed into the wall to allow the water resistant surface materials and substrate materials to pass down inside the perimeter upturn lip of the shower base (see Figure 10.2.19a and Figure 10.2.19b); and

be supported to prevent distortion or cracking.

Figure 10.2.19a Typical preformed shower base wall/floor junction

Figure Notes

Rebating of timber and steel framed walls must be in accordance with AS 1684 or NASH Standard Part 2 as appropriate.

Where rebating of masonry walls is required, it must be accommodated in the design in accordance with AS 3700.

Figure 10.2.19b Typical preformed shower base/floor junction on timber floors, including particleboard, plywood and other timber materials

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 10.2.19.

Defined terms used