11.2.5 Landings
Part 11.2 Stairway and ramp construction · NCC 2019: 3.9.1.5
(1) Landings must—
be not less than 750 mm long and where this involves a change in direction, the length is measured 500 mm from the inside edge of the landing (see Figure 11.2.5a); and
have a gradient not steeper than 1:50; and
be provided where the sill of a threshold of a doorway opens onto a stairway or ramp that provides a change in floor level or floor to ground level greater than 3 risers or 570 mm (see Figure 11.2.5b); and
extend across the full width of a doorway.
(2) In the case of a stairway serving only non-habitable rooms, such as attics, storerooms and the like that are not used on a regular or daily basis, the requirements of (1)(a) may be substituted with a minimum length of landing being not less than 600 mm long.
Figure 11.2.5a Landings
Figure 11.2.5b Threshold landing