4.2.14 Stiffened rafts Class A, S and M sites
Part 4.2 Footings, slabs and associated elements
Footing and stiffened raft slabs must comply with—
For Class A and S sites — Tables 4.2.14a, 4.2.14b and Figure 4.2.14a; and
For Class M sites — Table 4.2.14c and Figure 4.2.14b.
Table 4.2.14a Reinforcement for stiffened raft footings for Class A sites
Type of construction
Depth (D) (mm)
Bottom reinf.
Max. spacing c/l to c/l
Slab fabric
Clad frame
300
3-L8TM
N/A
SL72
Articulated masonry veneer
300
3-L8TM
N/A
SL72
Masonry veneer
300
3-L8TM
N/A
SL72
Articulated full masonry
400
3-L8TM
N/A
SL72
Full masonry
400
3-L8TM
N/A
SL72
Table Notes
Internal and external edge beams must be arranged to form an integral structural grid (see clauses 5.3.8 and 5.3.9 of AS 2870).
A 10% increase in spacings is permitted where the spacing in the other direction is 20% less than that specified.
Where external beams are wider than 300 mm, an extra bottom bar or equivalent of the same bar size is required for each 100 mm additional width.
Where a reinforced single leaf masonry wall is constructed directly above and structurally connected to a concrete edge beam, the beam may be reduced to 300 mm wide by 300 mm deep and reinforced with 3–L8TM reinforcement.
Alternative reinforcement sizes must comply with AS 2870.
Internal beam details and spacings must comply with Figure 4.2.14a or Figure 4.2.14b.
Table 4.2.14b Reinforcement for stiffened raft footings for Class S sites
Type of construction
Depth (D) (mm)
Bottom reinf.
Max. spacing c/l to c/l
Slab fabric
Clad frame
300
3-L8TM
N/A
SL72
Articulated masonry veneer
300
3-L8TM
N/A
SL72
Masonry veneer
300
3-L11TM
N/A
SL72
Articulated full masonry
450
3-L11TM
N/A
SL72
Full masonry
450
3-N16
5.0 (m) Note 2
SL82
Table Notes
Internal and external edge beams must be arranged to form an integral structural grid (see clauses 5.3.8 and 5.3.9 of AS 2870).
A 10% increase in spacings is permitted where the spacing in the other direction is 20% less than that specified.
Where external beams are wider than 300 mm, an extra bottom bar or equivalent of the same bar size is required for each 100 mm additional width.
Where a reinforced single leaf masonry wall is constructed directly above and structurally connected to a concrete edge beam, the beam may be reduced to 300 mm wide by 300 mm deep and reinforced with 3–L8TM reinforcement.
Alternative reinforcement sizes must comply with AS 2870.
Internal beam details and spacings must comply with Figure 4.2.14a or Figure 4.2.14b.
Table 4.2.14c Reinforcement for stiffened raft footings for Class M sites
Type of construction
Depth (D) (mm)
Bottom reinf.
Max. spacing c/l to c/l
Slab mesh
Clad frame
300
3-L11TM
6.0Note 2
SL72
Articulated masonry veneer
400
3-L11TM
6.0Note 2
SL72
Masonry veneer
400
3-L11TM
5.0Note 2
SL72
Articulated full masonry
500
3-L12TM
4.0
SL82
Full masonry
850
3-N16
4.0
SL92
Table Notes
Internal and external edge beams must be arranged to form an integral structural grid (see clauses 5.3.8 and 5.3.9 of AS 2870).
A 10% increase in spacings is permitted where the spacing in the other direction is 20% less than that specified.
Where external beams are wider than 300 mm, an extra bottom bar or equivalent of the same bar size is required for each 100 mm additional width.
Where a reinforced single leaf masonry wall is constructed directly above and structurally connected to a concrete edge beam, the beam may be reduced to 300 mm wide by 300 mm deep and reinforced with 3–L8TM reinforcement.
Alternative reinforcement sizes must comply with AS 2870.
Internal beam details and spacings must comply with Figure 4.2.14b.
Figure 4.2.14a Footing slab and stiffened raft slab details for Class A and S sites
Figure 4.2.14b Footing slab and stiffened raft slab details for Class M sites
Tables
- Table 4.2.14a Reinforcement for stiffened raft footings for Class A sites
- Table 4.2.14b Reinforcement for stiffened raft footings for Class S sites
- Table 4.2.14c Reinforcement for stiffened raft footings for Class M sites