Housing Provisions clause · ABCB Housing Provisions 2022

4.2.14 Stiffened rafts Class A, S and M sites

Part 4.2 Footings, slabs and associated elements

Open 4.2.14 on NCC Online ↗

Footing and stiffened raft slabs must comply with—

For Class A and S sites — Tables 4.2.14a, 4.2.14b and Figure 4.2.14a; and

For Class M sites — Table 4.2.14c and Figure 4.2.14b.

Table 4.2.14a Reinforcement for stiffened raft footings for Class A sites

Type of construction

Depth (D) (mm)

Bottom reinf.

Max. spacing c/l to c/l

Slab fabric

Clad frame

300

3-L8TM

N/A

SL72

Articulated masonry veneer

300

3-L8TM

N/A

SL72

Masonry veneer

300

3-L8TM

N/A

SL72

Articulated full masonry

400

3-L8TM

N/A

SL72

Full masonry

400

3-L8TM

N/A

SL72

Table Notes

Internal and external edge beams must be arranged to form an integral structural grid (see clauses 5.3.8 and 5.3.9 of AS 2870).

A 10% increase in spacings is permitted where the spacing in the other direction is 20% less than that specified.

Where external beams are wider than 300 mm, an extra bottom bar or equivalent of the same bar size is required for each 100 mm additional width.

Where a reinforced single leaf masonry wall is constructed directly above and structurally connected to a concrete edge beam, the beam may be reduced to 300 mm wide by 300 mm deep and reinforced with 3–L8TM reinforcement.

Alternative reinforcement sizes must comply with AS 2870.

Internal beam details and spacings must comply with Figure 4.2.14a or Figure 4.2.14b.

Table 4.2.14b Reinforcement for stiffened raft footings for Class S sites

Type of construction

Depth (D) (mm)

Bottom reinf.

Max. spacing c/l to c/l

Slab fabric

Clad frame

300

3-L8TM

N/A

SL72

Articulated masonry veneer

300

3-L8TM

N/A

SL72

Masonry veneer

300

3-L11TM

N/A

SL72

Articulated full masonry

450

3-L11TM

N/A

SL72

Full masonry

450

3-N16

5.0 (m) Note 2

SL82

Table Notes

Internal and external edge beams must be arranged to form an integral structural grid (see clauses 5.3.8 and 5.3.9 of AS 2870).

A 10% increase in spacings is permitted where the spacing in the other direction is 20% less than that specified.

Where external beams are wider than 300 mm, an extra bottom bar or equivalent of the same bar size is required for each 100 mm additional width.

Where a reinforced single leaf masonry wall is constructed directly above and structurally connected to a concrete edge beam, the beam may be reduced to 300 mm wide by 300 mm deep and reinforced with 3–L8TM reinforcement.

Alternative reinforcement sizes must comply with AS 2870.

Internal beam details and spacings must comply with Figure 4.2.14a or Figure 4.2.14b.

Table 4.2.14c Reinforcement for stiffened raft footings for Class M sites

Type of construction

Depth (D) (mm)

Bottom reinf.

Max. spacing c/l to c/l

Slab mesh

Clad frame

300

3-L11TM

6.0Note 2

SL72

Articulated masonry veneer

400

3-L11TM

6.0Note 2

SL72

Masonry veneer

400

3-L11TM

5.0Note 2

SL72

Articulated full masonry

500

3-L12TM

4.0

SL82

Full masonry

850

3-N16

4.0

SL92

Table Notes

Internal and external edge beams must be arranged to form an integral structural grid (see clauses 5.3.8 and 5.3.9 of AS 2870).

A 10% increase in spacings is permitted where the spacing in the other direction is 20% less than that specified.

Where external beams are wider than 300 mm, an extra bottom bar or equivalent of the same bar size is required for each 100 mm additional width.

Where a reinforced single leaf masonry wall is constructed directly above and structurally connected to a concrete edge beam, the beam may be reduced to 300 mm wide by 300 mm deep and reinforced with 3–L8TM reinforcement.

Alternative reinforcement sizes must comply with AS 2870.

Internal beam details and spacings must comply with Figure 4.2.14b.

Figure 4.2.14a Footing slab and stiffened raft slab details for Class A and S sites

Figure 4.2.14b Footing slab and stiffened raft slab details for Class M sites

Tables

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 4.2.14.

Defined terms used