Housing Provisions clause · ABCB Housing Provisions 2025

7.5.5 Eaves and soffit linings

Part 7.5 Timber and composite wall cladding · NCC 2019: 3.5.4.5

Open 7.5.5 on NCC Online ↗

Where provided, external fibre-cement sheets and linings used as eaves and soffit linings must—

comply with AS/NZS 2908.2 or ISO 8336; and

be fixed in accordance with Table 7.5.5 and Figure 7.5.5 using—

2.8 × 30 mm fibre-cement nails; or

No. 8 wafer head screws (for 4.5 mm and 6 mm sheets only); or

No. 8 self embedding head screws (for 6 mm sheets only).

Table 7.5.5 Trimmer and fastener spacings for 4.5 mm and 6 mm fibre-cement eaves and soffit linings

Maximum eaves width

Wind class

Maximum trimmer spacings (mm)

Maximum fastener spacings (mm)

Within 1200 mm of the external corners of the building

Elsewhere

Within 1200 mm of the external corners of the building

Elsewhere

600

N1

600

900

200

300

N2

600

800

200

300

N3

500

700

200

300

1200

N1

600

750

200

300

N2

600

700

200

300

N3

500

650

200

300

Figure 7.5.5 Eaves trimmer detail

Tables