New South Wales variation · ABCB Housing Provisions 2025

NSW 9.4.1 Fire separation

NSW Part 9.4 Fire protection of garage top dwellings · varies 9.4.1 Walls requiring protection

Open on NCC Online ↗

Insert NSW clause 9.4.1 in clause 9.4.1 as follows:

(1) A garage top dwelling must be separated from a non-associated private garage by a floor complying with NSW 9.4.2.

(2) Where a garage top dwelling is served by an internal stair, the garage top dwelling must be separated from a non-associated private garage by a wall complying with NSW 9.4.3.

(3) Where a garage top dwelling is located above both associated and non-associated private garages —

in addition to a floor required by (1), the private garages must be separated with a wall complying with NSW 9.4.3; or

where a garage top dwelling is not served by an internal stair, the garage top dwelling may be separated from the private garages by a floor complying with NSW 9.4.2.

Changed since NCC 2022. See ABCB Housing Provisions 2022 NSW 9.4.1, or show what changed.

Insert NSW clause 9.4.1 in clause 9.4.1 as follows: (1) A garage top dwelling must be separated from a … the private garages by a floor complying with NSW 9.4.2.

Removed words are struck through; added words are highlighted. Comparison of the text only.

The national clause