NT 13.2.3 Roofs
NT Part 13.2 Building fabric · varies 13.2.3 Roofs and ceilings
Insert NT clause 13.2.3 in clause 13.2.3 as follows:
(1) A roof must achieve the Total R-Value of 2.7 for the downwards direction of heat flow in climate zone 1 and downwards and upwards in climate zone 3.
(2) The Total R-Value is reduced to 2.2 for each of the following:
The roof upper surface has a solar absorptance value of not more than 0.55.
The roof space is ventilated by—
gable vents, ridge vents, eave vents, roof vents or the like that—
are evenly distributed to allow an unobstructed flow of air; and
are located to ensure, where practicable, there are no dead airspaces; and
have an aggregate fixed open area of not less than 1.0% of the ceiling area; or
not less than 2 wind-driven roof ventilators having an aggregate opening area of not less than 0.14 m2 in conjunction with gable vents, ridge vents, eave vents, roof vents or the like having an aggregate fixed open area of not less than 0.2% of the ceiling area; or
a tiled roof without sarking-type material at roof level.
(3) A roof that—
is required to achieve a minimum Total R-Value; and
has metal sheet roofing fixed to metal purlins, metal rafters or metal battens; and
does not have a ceiling lining or has a ceiling lining fixed directly to those metal purlins, metal rafters or metal battens,
must have a thermal break, consisting of a material with an R-Value of not less than 0.2, installed between the metal sheet roofing and its supporting member.
(4) A roof, or roof and associated ceiling, is deemed to have the Total R-Value required by Tables NT 13.2.3a, NT 13.2.3b and NT 13.2.3c.
(5) Where, for operational or safety reasons, ceiling insulation cannot be installed at or around exhaust fans or recessed downlights, a reduction of insulation of 1% or more of the ceiling area must be compensated for by proportionately increasing the R-Value of insulation in the remainder of the ceiling in accordance with Table NT 13.2.3d.
Insert NT table (13.2.3a) 13.2.3 as follows:
NT Table 13.2.3a: Typical insulation options for typical roof and ceiling construction: Unventilated roof spaces
|
Climate zone 1
Climate zone 3
Tiled roof (clay or concrete)
Total R-Value of roof and ceiling materials
0.43
0.37
Minimum value of added R-Value of insulation
2.27
2.33
Metal roof
Total R-Value of roof and ceiling materials
0.41
0.35
Minimum value of added R-Value of insulation
2.29
2.35
Minimum required Total R-Value
2.70
2.70
Insert NT table (13.2.3b) 13.2.3 as follows:
NT Table 13.2.3b: Typical insulation options for typical roof and ceiling construction: Pitched roof with flat ceiling – ventilated roof space
|
Climate zone 1
Climate zone 3
Tiled roof (clay or concrete)
Total R-Value of roof and ceiling materials
0.73
0.22
Minimum value of added R-Value of insulation
1.97
2.48
Metal roof
Total R-Value of roof and ceiling materials
0.71
0.20
Minimum value of added R-Value of insulation
1.99
2.50
Minimum required Total R-Value
2.70
2.70
Insert NT table (13.2.3c) 13.2.3 as follows:
NT Table 13.2.3c: Typical insulation options for typical roof and ceiling construction: Pitched roof with flat ceiling – unventilated roof space
|
Climate zone 1
Climate zone 3
Tiled roof (clay or concrete)
Total R-Value of roof and ceiling materials
0.55
0.40
Minimum value of added R-Value of insulation
2.15
2.30
Metal roof
Total R-Value of roof and ceiling materials
0.53
0.38
Minimum value of added R-Value of insulation
2.17
2.32
Minimum required Total R-Value
2.70
2.70
Insert NT table (13.2.3d) 13.2.3 as follows:
NT Table 13.2.3d: Adjusted minimum R-Value of ceiling insulation required to compensate for loss of ceiling insulation area
Percentage of ceiling area uninsulated
Minimum R-Value of ceiling insulation required to satisfy 13.2.3(1)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
0.5% to less than 1.0%
1.0
1.6
2.2
2.8
3.4
4.0
4.7
5.4
6.2
6.9
1.0% to less than 1.5%
1.1
1.7
2.3
2.9
3.6
4.4
5.2
6.1
7.0
X
1.5% to less than 2.0%
1.1
1.7
2.4
3.1
3.9
4.8
5.8
6.8
X
X
2.0% to less than 2.5%
1.1
1.8
2.5
3.3
4.2
5.3
6.5
X
X
X
2.5% to less than 3.0%
1.2
1.9
2.6
3.6
4.6
5.9
X
X
X
X
3.0% to less than 4.0%
1.2
2.0
3.0
4.2
5.7
X
X
X
X
X
4.0% to less than 5.0%
1.3
2.2
3.4
5.0
X
X
X
X
X
X
Changed since NCC 2022. See ABCB Housing Provisions 2022 NT 13.2.3, or show what changed.
Insert NT clause 13.2.3 in clause 13.2.3 as follows: (1) A roof must achieve the Total R-Value of 2.7 … 1.3 2.2 3.4 5.0 X X X X X X
Removed words are struck through; added words are highlighted. Comparison of the text only.