- NT 3.4.1 Requirements for termite management systemsDelete subclause 3.4.1(2) and insert NT 3.4.1(2) as follows: (2) For the purposes of (1), a primary building element consisting entirely of, or a…
- NT 3.4.2 Termite management systemsDelete clause 3.4.2 and insert NT 3.4.2 as follows: Where a termite management system is required it must— be selected appropriate to Table 3.4.2;…
- NT 10.7.1 Sound insulation requirementsInsert NT clause 10.7.1 in clause 10.7.1 as follows: (1) A separating wall between two or more Class 1 buildings must— achieve the weighted sound…
- NT 10.7.2 General installation requirements for wallsInsert NT clause 10.7.2 in clause 10.7.2 as follows: (1) To achieve an appropriate RW and impact sound resistance, walls must— be installed in…
- NT 10.7.3 Soil and waste pipesInsert NT clause 10.7.3 in clause 10.7.3 as follows: If a soil or waste pipe passes through a separating wall— a door or panel providing access to…
- NT 13.1.1 ScopeInsert NT clause 13.1.1 in clause 13.1.1 as follows: This Section sets out the following Deemed-to-Satisfy Provisions for energy efficiency:…
- NT 13.1.2 ApplicationInsert NT clause 13.1.2 in clause 13.1.2 as follows: The application of this Section is subject to the following: The Governing Requirements of NCC…
- NT 13.2.1 Application of Part 13.2Insert NT clause 13.2.1 in clause 13.2.1 as follows: (1) The provisions of NT 13.2.2 to NT 13.2.6 apply to— a Class 1 building; and a Class 10a…
- NT 13.2.2 Building fabric thermal insulationInsert NT clause 13.2.2 in clause 13.2.2 as follows: (1) Where required, insulation must comply with AS/NZS 4859.1 and be installed so that it—…
- NT 13.2.3 RoofsInsert NT clause 13.2.3 in clause 13.2.3 as follows: (1) A roof must achieve the Total R-Value of 2.7 for the downwards direction of heat flow in…
- NT 13.2.4 Roof lightsInsert NT clause 13.2.4 in clause 13.2.4 as follows: Roof lights serving a habitable room or an interconnecting space such as a corridor, hallway,…
- NT 13.2.5 External wallsInsert NT clause 13.2.5 in clause 13.2.5 as follows: (1) Each part of an external wall must satisfy (2) or (3), except for— an external wall facing…
- NT 13.2.6 Attached Class 10a buildingsInsert NT clause 13.2.6 in clause 13.2.6 as follows: A Class 10a building attached to a Class 1 building must— have an external fabric that achieves…
- NT 13.3.1 Application of Part 13.3Insert NT clause 13.3.1 in clause 13.3.1 as follows: This Part applies to— a Class 1 building; and a Class 10a building with a conditioned space.
- NT 13.3.2 External glazingInsert NT clause 13.3.2 in clause 13.3.2 as follows: Compliance with this part is demonstrated with a “passed” result produced with the ABCB Glazing…
- NT 13.3.3 ShadingInsert NT clause 13.3.3 in clause 13.3.3 as follows: Where shading is required to comply with NT 13.3.2, it must— be provided by an external…
- NT 13.4.1 Application of Part 13.4Insert NT clause 13.4.1 in clause 13.4.1 as follows: This Part applies to— a Class 1 building; and a Class 10a building with a conditioned space.…
- NT 13.4.2 Chimneys and fluesInsert NT clause 13.4.2 in clause 13.4.2 as follows: The chimney or flue of an open solid-fuel burning appliance must be provided with a damper or…
- NT 13.4.3 Roof lightsInsert NT clause 13.4.3 in clause 13.4.3 as follows: (1) A roof light must be sealed, or capable of being sealed, when serving a conditioned space.…
- NT 13.4.4 External windows and doorsInsert NT clause 13.4.4 in clause 13.4.4 as follows: (1) A seal to restrict air infiltration must be fitted to each edge of an external door,…
- NT 13.4.5 Exhaust fansInsert NT clause 13.4.5 in clause 13.4.5 as follows: An exhaust fan must be fitted with a sealing device such as a self-closing damper, filter or…
- NT 13.4.6 Construction of ceilings, walls and floorsInsert NT clause 13.4.6 in clause 13.4.6 as follows: (1) Ceilings, walls, floors and any opening such as a window frame, door frame, roof light…
- NT 13.4.7 Evaporative coolersInsert NT clause 13.4.7 in clause 13.4.7 as follows: An evaporative cooler must be fitted with a self-closing damper or the like when serving a…
- NT 13.5.1 Application of Part 13.5Insert NT clause 13.5.1 in clause 13.5.1 as follows: This Part applies to a habitable room in a Class 1 building.
- NT 13.5.2 Air movementInsert NT clause 13.5.2 in clause 13.5.2 as follows: (1) Air movement must be provided to habitable rooms in accordance with Table NT 13.5.2. (2)…
- NT 13.5.3 Ventilation openingsInsert NT clause 13.5.3 in clause 13.5.3 as follows: (1) The total ventilation opening area required by Table NT 13.5.2 to a habitable room must— be…
- NT 13.7.1 Application of Part 13.7Insert NT clause 13.7.1 in clause 13.7.1 as follows: This Part applies to— a Class 1 building; and a Class 10a building.
- NT 13.7.2 Insulation of servicesInsert NT clause 13.7.2 in clause 13.7.2 as follows: Thermal insulation for central heating water piping and heating and cooling ductwork must be—…
- NT 13.7.3 Central heating water pipingInsert NT clause 13.7.3 in clause 13.7.3 as follows: (1) Central heating water piping that is not within a conditioned space must be thermally…
- NT 13.7.4 Heating and cooling ductworkInsert NT clause 13.7.4 in clause 13.7.4 as follows: (1) Heating and cooling ductwork and fittings must— achieve the minimum Total R-Value in…
- NT 13.7.5 Water heater in a heated water supply systemInsert NT clause 13.7.5 in clause 13.7.5 as follows: A water heater in a heated water supply system must be designed and installed in accordance…