- 5.3.1 ApplicationPart 5.3 applies subject to the limitations set out in H1D5(2)(c). (2) Part 5.3 need not be complied with if H1D5(2)(a) or (b) are complied with.
- 5.3.2 Height of wall limitationCavity masonry walls must not be greater than 8.5 m in height when measured above the adjacent finished ground level.
- Table 5.3.3 Spacing of return walls for cavity walls with openings — distance from the edge of an opening (mm)Wind class | Opening width (mm) 900 | 1500 | 2100 | 2700 N3 | 2100 | 1800 | 800 | 400 N2 | 3200 | 2900 | 2600 | 2300 N1 | 2500(Note) | 2200(Note) |…
- 5.3.3 External wallsCavity masonry walls must comply with the relevant provisions of this Part and Parts 5.6 and 5.7, and be constructed as follows: The height of the…
- 5.3.4 Internal wallsWhere internal masonry walls intersect with other internal or external walls they must comply with the relevant provisions of this Part and be— not…
- 5.3.5 Openings in cavity masonryExcept where excluded by (2), openings in cavity masonry must be spanned by steel lintels in accordance with 5.6.7. (2) Openings in cavity masonry…
- 5.3.6 Damp-proof courses and flashing materialsDamp-proof courses and flashing must be provided in accordance with 5.7.3 and 5.7.4.
- 5.3.7 Vertical articulation jointsVertical articulation joints are to be installed in accordance with 5.6.8.