Table · ABCB Housing Provisions 2025
Table 13.2.3r Flat, skillion or cathedral roof – minimum R-Value for ceiling insulation: climate zone 8
| Reflective insulation under-roof | SA ≤ 0.23 | 0.23 < SA ≤ 0.32 | 0.32 < SA ≤ 0.42 | 0.42 < SA ≤ 0.53 | 0.53 < SA ≤ 0.64 | 0.64 < SA ≤ 0.73 | 0.73 < SA ≤ 0.85 | 0.85 < SA ≤ 0.96 |
|---|---|---|---|---|---|---|---|---|
| Yes | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 3.5 | 3.5 | 3.5 |
| No | 4.5 | 4.0 | 4.0 | 3.5 | 3.5 | 3.0 | 3.0 | 3.0 |
Table Notes
SA = solar absorptance.
The R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.
The R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.
R-Values listed are for the labelled, declared R-Value of insulation.
Table for 13.2.3 Roofs and ceilings
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.2.3r.