Table · ABCB Housing Provisions 2025

Table 13.2.5b Lightweight walls – minimum insulation R-Value: climate zone 1

Part 13.2 Building fabric

Open Table 13.2.5b on NCC Online ↗
SAOverhang (mm)Wall height (m)
≤ 2.4> 2.4 to ≤ 2.7> 2.7 to ≤ 3.0> 3.0 to ≤ 3.6
≤ 0.30XXXX
> 0 to ≤ 3002.5XXX
> 300 to ≤ 4501.0XXX
> 450 to ≤ 600Reflective2.0XX
> 600 to ≤ 900Reflective1.02.0X
> 900 to ≤ 1200ReflectiveReflective1.0X
> 1200 to ≤ 1500ReflectiveReflectiveReflective2.5
> 1500 to ≤ 18000.0ReflectiveReflective1.5
> 18000.00.0Reflective1.0
> 0.3 to ≤ 0.40XXXX
> 0 to ≤ 300XXXX
> 300 to ≤ 4501.0XXX
> 450 to ≤ 600Reflective2.0XX
> 600 to ≤ 900Reflective1.02.0X
> 900 to ≤ 1200ReflectiveReflective1.0X
>1200 to ≤ 1500ReflectiveReflectiveReflective2.5
> 1500 to ≤ 18000.0ReflectiveReflective1.5
> 18000.00.0Reflective1.0
> 0.4 to ≤ 0.50XXXX
> 0 to ≤ 300XXXX
> 300 to ≤ 4501.0XXX
> 450 to ≤ 600Reflective2.0XX
> 600 to ≤ 900Reflective1.02.0X
> 900 to ≤ 1200ReflectiveReflective1.0X
> 1200 to ≤ 1500ReflectiveReflectiveReflective2.5
> 1500 to ≤ 18000.0ReflectiveReflective1.5
> 18000.00.0Reflective1.0
> 0.5 to ≤ 0.60XXXX
> 0 to ≤ 300XXXX
> 300 to ≤ 4501.0XXX
> 450 to ≤ 600Reflective2.0XX
> 600 to ≤ 900Reflective1.02.0X
> 900 to ≤ 1200ReflectiveReflective1.0X
> 1200 to ≤ 1500ReflectiveReflectiveReflective2.5
> 1500 to ≤ 18000.0ReflectiveReflective1.5
> 18000.00.0Reflective1.0
> 0.6 to ≤ 0.70XXXX
> 0 to ≤ 300XXXX
> 300 to ≤ 4501.0XXX
> 450 to ≤ 600Reflective2.0XX
> 600 to ≤ 900Reflective1.02.0X
> 900 to ≤ 1200ReflectiveReflective1.0X
> 1200 to ≤ 1500ReflectiveReflectiveReflective2.5
> 1500 to ≤ 18000.0ReflectiveReflective1.5
> 18000.00.0Reflective1.0

Table Notes

SA = solar absorptance.

R-Values listed are for the labelled, declared R-Value of insulation.

X = not permitted.

Reflective = reflective insulation with an airspace with a minimum width of at least 20 mm. The surface emittance of the reflective surface facing the airspace must be a maximum of 0.1 where the airspace is exposed to the sun during construction to reduce glare (an outward facing surface), or 0.05 of not exposed to the sun (an inward facing surface).

This Table shows wall heights for single storey dwellings. For two storey (or more) dwellings with a wall height up to 2.4 m, add R0.5 to R-Values from this Table. For two storey (or more) dwellings with a wall height greater than 2.4 m, add R1.0.

Table for 13.2.5 External walls

Changed since NCC 2022. See ABCB Housing Provisions 2022 Table 13.2.5b, or show what changed.

SA | Overhang (mm) | Wall height (m) ≤ 2.4 … | 0.0 | Reflective | Reflective | 1.5 > 1800 to ≤ 2400 | 0.0 | 0.0 | Reflective | 1.0 > 0.3 … | 0.0 | Reflective | Reflective | 1.5 > 1800 to ≤ 2400 | 0.0 | 0.0 | Reflective | 1.0 > 0.4 … | 0.0 | Reflective | Reflective | 1.5 > 1800 to ≤ 2400 | 0.0 | 0.0 | Reflective | 1.0 > 0.5 … | 0.0 | Reflective | Reflective | 1.5 > 1800 to ≤ 2400 | 0.0 | 0.0 | Reflective | 1.0 > 0.6 … | 0.0 | Reflective | Reflective | 1.5 > 1800 to ≤ 2400 | 0.0 | 0.0 | Reflective | 1.0 Table Notes … with a wall height greater than 2.4 m, add R1.0.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used