Table 13.2.5j Masonry cavity wall – minimum insulation R-Value: climate zone 5
| SA | Overhang (mm) | Wall height (m) | |||
|---|---|---|---|---|---|
| ≤ 2.4 | > 2.4 to ≤ 2.7 | > 2.7 to ≤ 3.0 | > 3.0 to ≤ 3.6 | ||
| ≤ 0.35 | 0 | 0.0 | 0.0 | 0.25 | 0.25 |
| > 0 to ≤ 300 | 0.0 | 0.25 | 0.25 | 0.25 | |
| > 300 to ≤ 450 | 0.25 | 0.25 | 0.25 | 0.25 | |
| > 450 to ≤ 600 | 0.25 | 0.25 | 0.25 | 0.25 | |
| > 600 to ≤ 900 | 0.25 | 0.25 | 0.25 | 0.51 | |
| > 900 to ≤ 1200 | 0.51 | 0.51 | 0.51 | 0.51 | |
| > 1200 to ≤ 1500 | 0.62 | 0.51 | 0.51 | 0.51 | |
| > 0.35 to ≤ 0.5 | 0 | 0.0 | 0.0 | 0.25 | 0.25 |
| > 0 to ≤ 300 | 0.0 | 0.0 | 0.25 | 0.25 | |
| > 300 to ≤ 450 | 0.0 | 0.25 | 0.25 | 0.25 | |
| > 450 to ≤ 600 | 0.25 | 0.25 | 0.25 | 0.25 | |
| > 600 to ≤ 900 | 0.25 | 0.25 | 0.25 | 0.25 | |
| > 900 to ≤ 1200 | 0.51 | 0.25 | 0.25 | 0.51 | |
| > 1200 to ≤ 1500 | 0.62 | 0.51 | 0.51 | 0.51 | |
| > 0.5 to ≤ 0.7 | 0 | 0.0 | 0.0 | 0.0 | 0.25 |
| > 0 to ≤ 300 | 0.0 | 0.0 | 0.25 | 0.25 | |
| > 300 to ≤ 450 | 0.0 | 0.0 | 0.25 | 0.25 | |
| > 450 to ≤ 600 | 0.25 | 0.25 | 0.25 | 0.25 | |
| > 600 to ≤ 900 | 0.25 | 0.25 | 0.25 | 0.25 | |
| > 900 to ≤ 1200 | 0.51 | 0.25 | 0.25 | 0.25 | |
| > 1200 to ≤ 1500 | 0.51 | 0.51 | 0.51 | 0.51 |
Table Notes
SA = solar absorptance.
R-Values listed are for the labelled, declared R-Value of insulation.
This Table shows wall heights for single storey dwellings. For two (or more) storey dwellings, add R0.25 to the R-Values shown in this Table.
Where an overhang of > 1500 mm is used, the values for > 1200 to ≤ 1500 apply provided no more than 15% of the total opaque wall area of the dwelling (excluding windows/doors) is covered by overhangs > 1500 mm.
Table for 13.2.5 External walls
Changed since NCC 2022. See ABCB Housing Provisions 2022 Table 13.2.5j, or show what changed.
SA | Overhang (mm) | Wall height (m) ≤ 2.4 … dwellings, add R0.25 to the R-Values shown in this Table. Where an overhang of > 1500 mm is used, the values for > 1200 to ≤ 1500 apply provided no more than 15% of the total opaque wall area of the dwelling (excluding windows/doors) is covered by overhangs > 1500 mm.
Removed words are struck through; added words are highlighted. Comparison of the text only.