Table · ABCB Housing Provisions 2025

Table 13.2.5j Masonry cavity wall – minimum insulation R-Value: climate zone 5

Part 13.2 Building fabric

Open Table 13.2.5j on NCC Online ↗
SAOverhang (mm)Wall height (m)
≤ 2.4> 2.4 to ≤ 2.7> 2.7 to ≤ 3.0> 3.0 to ≤ 3.6
≤ 0.3500.00.00.250.25
> 0 to ≤ 3000.00.250.250.25
> 300 to ≤ 4500.250.250.250.25
> 450 to ≤ 6000.250.250.250.25
> 600 to ≤ 9000.250.250.250.51
> 900 to ≤ 12000.510.510.510.51
> 1200 to ≤ 15000.620.510.510.51
> 0.35 to ≤ 0.500.00.00.250.25
> 0 to ≤ 3000.00.00.250.25
> 300 to ≤ 4500.00.250.250.25
> 450 to ≤ 6000.250.250.250.25
> 600 to ≤ 9000.250.250.250.25
> 900 to ≤ 12000.510.250.250.51
> 1200 to ≤ 15000.620.510.510.51
> 0.5 to ≤ 0.700.00.00.00.25
> 0 to ≤ 3000.00.00.250.25
> 300 to ≤ 4500.00.00.250.25
> 450 to ≤ 6000.250.250.250.25
> 600 to ≤ 9000.250.250.250.25
> 900 to ≤ 12000.510.250.250.25
> 1200 to ≤ 15000.510.510.510.51

Table Notes

SA = solar absorptance.

R-Values listed are for the labelled, declared R-Value of insulation.

This Table shows wall heights for single storey dwellings. For two (or more) storey dwellings, add R0.25 to the R-Values shown in this Table.

Where an overhang of > 1500 mm is used, the values for > 1200 to ≤ 1500 apply provided no more than 15% of the total opaque wall area of the dwelling (excluding windows/doors) is covered by overhangs > 1500 mm.

Table for 13.2.5 External walls

Changed since NCC 2022. See ABCB Housing Provisions 2022 Table 13.2.5j, or show what changed.

SA | Overhang (mm) | Wall height (m) ≤ 2.4 … dwellings, add R0.25 to the R-Values shown in this Table. Where an overhang of > 1500 mm is used, the values for > 1200 to ≤ 1500 apply provided no more than 15% of the total opaque wall area of the dwelling (excluding windows/doors) is covered by overhangs > 1500 mm.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used