Table · ABCB Housing Provisions 2025

Table 13.3.2m Orientation sector winter exposure factor (EW) — suspended floor: climate zone 6

Part 13.3 External glazing

Open Table 13.3.2m on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.621.311.160.720.490.901.101.44
0.051.561.241.060.600.410.761.011.37
0.101.551.191.020.570.390.720.951.34
0.201.331.070.900.510.350.640.881.23
0.401.220.930.770.430.300.540.751.04
0.601.040.790.650.370.260.460.650.90
0.800.920.670.550.330.240.440.580.75
1.000.730.530.490.300.220.380.490.65
1.200.600.500.420.290.200.360.450.55
1.400.450.380.380.250.200.340.400.49
1.600.370.340.320.240.180.300.350.42
1.800.270.280.300.220.170.280.340.38
2.000.210.250.290.210.160.280.300.30

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.2m.