13.3.2 External glazing — winter
Part 13.3 External glazing · NCC 2019: 3.12.2.1
(1) In climate zones 2 to 8, the ratio of the conductance (Cu) and solar heat gain (CSHGC) of the glazing in each storey, including any mezzanine, must—
not exceed the allowances obtained from Table 13.3.2a; and
be calculated in accordance with the following formula: [formula] (2) In the formula at (1)(b)—
[formula] = the area of each glazing element; and
[formula] = the Total System U-Value of each glazing element; and
[formula] = the Total System SHGC for each glazing element, not exceeding 0.7; and
[formula] = the winter exposure factor for each glazing element obtained from Table 13.3.2b, 13.3.2c, 13.3.2d, 13.3.2e, 13.3.2f, 13.3.2g, 13.3.2h, 13.3.2i, 13.3.2j, 13.3.2k, 13.3.2l, 13.3.2m, 13.3.2n, 13.3.2o, 13.3.2p or 13.3.2q; and
[formula] = the bedroom conductance factor obtained from Table 13.3.2r; and
[formula] = the orientation sector conductance factor obtained from Table 13.3.2s, 13.3.2t, 13.3.2u, 13.3.2v, 13.3.2w, 13.3.2x or 13.3.2y; and
[formula] = the room type factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag; and
[formula] = the bedroom solar heat gain factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag; and
[formula] = the factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag for each glazing element located on a floor level above the lowest floor level; and
[formula] = the frame factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag for each glazing element; and
[formula] = the floor factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag for each glazing element.
(3) For the purposes of this clause—
orientation sectors must be determined in accordance with Figure 13.3.2a; and
P/H must be determined in accordance with Figure 13.3.2b.
Table 13.3.2a Maximum conductance to solar heat gain ratio (CU/CSHGC)
Climate zone
Floor in direct contact with the ground
Suspended floor
2
9.60
9.37
3
19.10
14.75
4
10.25
8.04
5 (lightweight wall)
8.89
8.32
5 (concrete or masonry wall)
8.79
10.12
6
8.45
6.06
7
7.02
7.96
8
4.93
9.41
Table 13.3.2b Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 2
P/H
North
North east
East
South east
South
South west
West
North west
0.00
1.49
1.48
1.08
0.47
0.41
0.46
1.05
1.44
0.05
1.44
1.40
1.00
0.40
0.34
0.41
0.97
1.38
0.10
1.38
1.36
0.95
0.38
0.32
0.38
0.93
1.31
0.20
1.21
1.21
0.85
0.34
0.30
0.34
0.84
1.17
0.40
1.00
0.97
0.68
0.28
0.25
0.28
0.70
0.97
0.60
0.83
0.80
0.60
0.25
0.22
0.25
0.59
0.81
0.80
0.62
0.64
0.49
0.21
0.21
0.23
0.51
0.66
1.00
0.43
0.54
0.40
0.20
0.20
0.19
0.43
0.55
1.20
0.26
0.43
0.35
0.18
0.19
0.18
0.40
0.45
1.40
0.22
0.37
0.29
0.16
0.18
0.17
0.36
0.37
1.60
0.18
0.30
0.28
0.16
0.17
0.16
0.30
0.33
1.80
0.15
0.26
0.24
0.15
0.15
0.15
0.26
0.27
2.00
0.12
0.19
0.21
0.14
0.15
0.15
0.25
0.26
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table 13.3.2c Orientation sector winter exposure factor (EW) — suspended floor: climate zone 2
P/H
North
North east
East
South east
South
South west
West
North west
0.00
1.67
1.36
1.20
0.52
0.19
0.85
1.18
1.51
0.05
1.62
1.29
1.12
0.45
0.16
0.75
1.09
1.45
0.10
1.56
1.26
1.06
0.42
0.15
0.71
1.05
1.37
0.20
1.36
1.11
0.95
0.38
0.14
0.62
0.95
1.22
0.40
1.13
0.90
0.76
0.31
0.12
0.52
0.79
1.01
0.60
0.94
0.74
0.67
0.28
0.10
0.46
0.66
0.85
0.80
0.70
0.59
0.55
0.24
0.10
0.41
0.57
0.69
1.00
0.49
0.50
0.45
0.22
0.09
0.35
0.48
0.57
1.20
0.30
0.40
0.39
0.20
0.09
0.33
0.46
0.47
1.40
0.25
0.34
0.32
0.18
0.08
0.31
0.40
0.39
1.60
0.20
0.27
0.31
0.18
0.08
0.29
0.34
0.35
1.80
0.17
0.24
0.27
0.17
0.07
0.27
0.30
0.29
2.00
0.14
0.18
0.24
0.16
0.07
0.27
0.29
0.28
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table 13.3.2d Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 3
P/H
North
North east
East
South east
South
South west
West
North west
0.00
1.36
1.16
0.75
0.38
0.38
0.43
1.05
1.41
0.05
1.35
1.12
0.70
0.33
0.33
0.38
1.00
1.38
0.10
1.25
1.07
0.66
0.32
0.32
0.37
0.96
1.30
0.20
1.11
0.95
0.60
0.28
0.30
0.33
0.86
1.18
0.40
0.89
0.78
0.51
0.24
0.27
0.27
0.74
0.98
0.60
0.67
0.60
0.41
0.21
0.26
0.23
0.59
0.79
0.80
0.45
0.48
0.37
0.19
0.23
0.22
0.51
0.63
1.00
0.30
0.41
0.30
0.17
0.21
0.21
0.45
0.51
1.20
0.21
0.31
0.26
0.15
0.21
0.18
0.37
0.43
1.40
0.16
0.28
0.21
0.14
0.20
0.17
0.33
0.37
1.60
0.12
0.24
0.20
0.13
0.18
0.16
0.32
0.31
1.80
0.11
0.17
0.16
0.13
0.18
0.14
0.26
0.28
2.00
0.09
0.17
0.15
0.12
0.18
0.14
0.24
0.24
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table 13.3.2e Orientation sector winter exposure factor (EW) — suspended floor: climate zone 3
P/H
North
North east
East
South east
South
South west
West
North west
0.00
1.92
1.29
0.97
0.82
0.75
1.07
1.24
1.69
0.05
1.90
1.24
0.90
0.72
0.66
0.94
1.18
1.65
0.10
1.76
1.18
0.86
0.69
0.63
0.91
1.13
1.56
0.20
1.57
1.05
0.77
0.62
0.60
0.81
1.01
1.41
0.40
1.25
0.86
0.66
0.51
0.54
0.68
0.87
1.17
0.60
0.94
0.66
0.53
0.46
0.51
0.59
0.70
0.94
0.80
0.63
0.53
0.47
0.41
0.45
0.55
0.60
0.76
1.00
0.42
0.45
0.39
0.36
0.42
0.52
0.53
0.61
1.20
0.29
0.35
0.34
0.33
0.42
0.46
0.44
0.52
1.40
0.23
0.31
0.28
0.31
0.39
0.42
0.39
0.44
1.60
0.17
0.27
0.26
0.28
0.36
0.39
0.38
0.37
1.80
0.15
0.19
0.21
0.28
0.36
0.36
0.31
0.34
2.00
0.13
0.19
0.20
0.26
0.36
0.36
0.29
0.29
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table 13.3.2f Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 4
P/H
North
North east
East
South east
South
South west
West
North west
0.00
1.48
1.40
0.91
0.47
0.46
0.51
1.11
1.57
0.05
1.45
1.34
0.84
0.40
0.38
0.43
1.03
1.51
0.10
1.43
1.30
0.81
0.37
0.36
0.40
0.98
1.46
0.20
1.22
1.18
0.74
0.34
0.33
0.36
0.88
1.31
0.40
1.11
1.01
0.62
0.29
0.29
0.31
0.75
1.13
0.60
0.92
0.83
0.54
0.25
0.25
0.27
0.64
0.92
0.80
0.80
0.68
0.47
0.23
0.23
0.25
0.57
0.77
1.00
0.64
0.61
0.41
0.20
0.21
0.22
0.48
0.66
1.20
0.46
0.47
0.36
0.18
0.21
0.21
0.44
0.57
1.40
0.35
0,43
0.33
0.17
0.20
0.20
0.39
0.48
1.60
0.26
0.38
0.31
0.17
0.18
0.18
0.34
0.42
1.80
0.20
0.32
0.28
0.16
0.18
0.17
0.31
0.36
2.00
0.18
0.30
0.24
0.14
0.17
0.16
0.29
0.30
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table 13.3.2g Orientation sector winter exposure factor (EW) — suspended floor: climate zone 4
P/H
North
North east
East
South east
South
South west
West
North west
0.00
1.38
1.12
1.00
0.71
0.56
0.87
1.02
1.26
0.05
1.35
1.08
0.91
0.60
0.46
0.73
0.95
1.21
0.10
1.34
1.04
0.89
0.56
0.45
0.69
0.90
1.17
0.20
1.13
0.95
0.80
0.51
0.40
0.62
0.82
1.05
0.40
1.04
0.81
0.67
0.43
0.35
0.53
0.70
0.91
0.60
0.85
0.67
0.59
0.38
0.30
0.47
0.59
0.74
0.80
0.74
0.55
0.52
0.34
0.29
0.42
0.53
0.62
1.00
0.60
0.49
0.44
0.31
0.26
0.38
0.44
0.53
1.20
0.43
0.38
0.40
0.27
0.26
0.36
0.41
0.46
1.40
0.33
0.35
0.36
0.25
0.24
0.33
0.36
0.39
1.60
0.24
0.31
0.34
0.25
0.22
0.31
0.31
0.34
1.80
0.18
0.26
0.30
0.24
0.22
0.29
0.29
0.29
2.00
0.17
0.24
0.26
0.22
0.21
0.27
0.26
0.24
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table 13.3.2h Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 5 (lightweight wall)
P/H
North
North east
East
South east
South
South west
West
North west
0.00
1.61
1.55
1.00
0.49
0.44
0.47
1.02
1.58
0.05
1.56
1.49
0.91
0.41
0.37
0.40
0.94
1.51
0.10
1.56
1.43
0.86
0.39
0.36
0.38
0.90
1.47
0.20
1.30
1.27
0.77
0.35
0.32
0.34
0.80
1.32
0.40
1.19
1.05
0.64
0.30
0.28
0.29
0.66
1.10
0.60
0.97
0.87
0.52
0.26
0.25
0.25
0.56
0.90
0.80
0.78
0.71
0.46
0.24
0.23
0.23
0.50
0.73
1.00
0.64
0.55
0.36
0.21
0.22
0.20
0.43
0.63
1.20
0.43
0.48
0.33
0.20
0.20
0.19
0.35
0.50
1.40
0.32
0.36
0.27
0.1
Tables
- Table 13.3.2a Maximum conductance to solar heat gain ratio (CU/CSHGC)
- Table 13.3.2b Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 2
- Table 13.3.2c Orientation sector winter exposure factor (EW) — suspended floor: climate zone 2
- Table 13.3.2d Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 3
- Table 13.3.2e Orientation sector winter exposure factor (EW) — suspended floor: climate zone 3
- Table 13.3.2f Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 4
- Table 13.3.2g Orientation sector winter exposure factor (EW) — suspended floor: climate zone 4
- Table 13.3.2h Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 5 (lightweight wall)
- Table 13.3.2i Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 5 (concrete or masonry wall)
- Table 13.3.2j Orientation sector winter exposure factor (EW) — suspended floor: climate zone 5 (lightweight wall)
- Table 13.3.2k Orientation sector winter exposure factor (EW) — suspended floor: climate zone 5 (concrete or masonry wall)
- Table 13.3.2l Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 6
- Table 13.3.2m Orientation sector winter exposure factor (EW) — suspended floor: climate zone 6
- Table 13.3.2n Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 7
- Table 13.3.2o Orientation sector winter exposure factor (EW) — suspended floor: climate zone 7
- Table 13.3.2p Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 8
- Table 13.3.2q Orientation sector winter exposure factor (EW) — suspended floor — climate zone 8
- Table 13.3.2r Bedroom conductance factor (BC)
- Table 13.3.2s Orientation sector conductance factor (OC): climate zone 2
- Table 13.3.2t Orientation sector conductance factor (OC): climate zone 3
- Table 13.3.2u Orientation sector conductance factor (OC): climate zone 4
- Table 13.3.2v Orientation sector conductance factor (OC): climate zone 5
- Table 13.3.2w Orientation sector conductance factor (OC): climate zone 6
- Table 13.3.2x Orientation sector conductance factor (OC): climate zone 7
- Table 13.3.2y Orientation sector conductance factor (OC): climate zone 8
- Table 13.3.2z Winter solar heat gain factors: climate zone 2
- Table 13.3.2aa Winter solar heat gain factor: climate zone 3
- Table 13.3.2ab Winter solar heat gain factors: climate zone 4
- Table 13.3.2ac Winter solar heat gain factors: climate zone 5 — lightweight or masonry veneer wall
- Table 13.3.2ad Winter solar heat gain factors: climate zone 5 — concrete or masonry wall
- Table 13.3.2ae Winter solar heat gain factors: climate zone 6
- Table 13.3.2af Winter solar heat gain factors: climate zone 7
- Table 13.3.2ag Winter solar heat gain factors: climate zone 8