Housing Provisions clause · ABCB Housing Provisions 2025

13.3.2 External glazing — winter

Part 13.3 External glazing · NCC 2019: 3.12.2.1

Open 13.3.2 on NCC Online ↗
Varied in NT. Check the variation for your state.

(1) In climate zones 2 to 8, the ratio of the conductance (Cu) and solar heat gain (CSHGC) of the glazing in each storey, including any mezzanine, must—

not exceed the allowances obtained from Table 13.3.2a; and

be calculated in accordance with the following formula: [formula] (2) In the formula at (1)(b)—

[formula] = the area of each glazing element; and

[formula] = the Total System U-Value of each glazing element; and

[formula] = the Total System SHGC for each glazing element, not exceeding 0.7; and

[formula] = the winter exposure factor for each glazing element obtained from Table 13.3.2b, 13.3.2c, 13.3.2d, 13.3.2e, 13.3.2f, 13.3.2g, 13.3.2h, 13.3.2i, 13.3.2j, 13.3.2k, 13.3.2l, 13.3.2m, 13.3.2n, 13.3.2o, 13.3.2p or 13.3.2q; and

[formula] = the bedroom conductance factor obtained from Table 13.3.2r; and

[formula] = the orientation sector conductance factor obtained from Table 13.3.2s, 13.3.2t, 13.3.2u, 13.3.2v, 13.3.2w, 13.3.2x or 13.3.2y; and

[formula] = the room type factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag; and

[formula] = the bedroom solar heat gain factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag; and

[formula] = the factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag for each glazing element located on a floor level above the lowest floor level; and

[formula] = the frame factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag for each glazing element; and

[formula] = the floor factor in Table 13.3.2z, 13.3.2aa, 13.3.2ab, 13.3.2ac, 13.3.2ad, 13.3.2ae, 13.3.2af or 13.3.2ag for each glazing element.

(3) For the purposes of this clause—

orientation sectors must be determined in accordance with Figure 13.3.2a; and

P/H must be determined in accordance with Figure 13.3.2b.

Table 13.3.2a Maximum conductance to solar heat gain ratio (CU/CSHGC)

Climate zone

Floor in direct contact with the ground

Suspended floor

2

9.60

9.37

3

19.10

14.75

4

10.25

8.04

5 (lightweight wall)

8.89

8.32

5 (concrete or masonry wall)

8.79

10.12

6

8.45

6.06

7

7.02

7.96

8

4.93

9.41

Table 13.3.2b Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 2

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.49

1.48

1.08

0.47

0.41

0.46

1.05

1.44

0.05

1.44

1.40

1.00

0.40

0.34

0.41

0.97

1.38

0.10

1.38

1.36

0.95

0.38

0.32

0.38

0.93

1.31

0.20

1.21

1.21

0.85

0.34

0.30

0.34

0.84

1.17

0.40

1.00

0.97

0.68

0.28

0.25

0.28

0.70

0.97

0.60

0.83

0.80

0.60

0.25

0.22

0.25

0.59

0.81

0.80

0.62

0.64

0.49

0.21

0.21

0.23

0.51

0.66

1.00

0.43

0.54

0.40

0.20

0.20

0.19

0.43

0.55

1.20

0.26

0.43

0.35

0.18

0.19

0.18

0.40

0.45

1.40

0.22

0.37

0.29

0.16

0.18

0.17

0.36

0.37

1.60

0.18

0.30

0.28

0.16

0.17

0.16

0.30

0.33

1.80

0.15

0.26

0.24

0.15

0.15

0.15

0.26

0.27

2.00

0.12

0.19

0.21

0.14

0.15

0.15

0.25

0.26

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table 13.3.2c Orientation sector winter exposure factor (EW) — suspended floor: climate zone 2

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.67

1.36

1.20

0.52

0.19

0.85

1.18

1.51

0.05

1.62

1.29

1.12

0.45

0.16

0.75

1.09

1.45

0.10

1.56

1.26

1.06

0.42

0.15

0.71

1.05

1.37

0.20

1.36

1.11

0.95

0.38

0.14

0.62

0.95

1.22

0.40

1.13

0.90

0.76

0.31

0.12

0.52

0.79

1.01

0.60

0.94

0.74

0.67

0.28

0.10

0.46

0.66

0.85

0.80

0.70

0.59

0.55

0.24

0.10

0.41

0.57

0.69

1.00

0.49

0.50

0.45

0.22

0.09

0.35

0.48

0.57

1.20

0.30

0.40

0.39

0.20

0.09

0.33

0.46

0.47

1.40

0.25

0.34

0.32

0.18

0.08

0.31

0.40

0.39

1.60

0.20

0.27

0.31

0.18

0.08

0.29

0.34

0.35

1.80

0.17

0.24

0.27

0.17

0.07

0.27

0.30

0.29

2.00

0.14

0.18

0.24

0.16

0.07

0.27

0.29

0.28

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table 13.3.2d Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 3

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.36

1.16

0.75

0.38

0.38

0.43

1.05

1.41

0.05

1.35

1.12

0.70

0.33

0.33

0.38

1.00

1.38

0.10

1.25

1.07

0.66

0.32

0.32

0.37

0.96

1.30

0.20

1.11

0.95

0.60

0.28

0.30

0.33

0.86

1.18

0.40

0.89

0.78

0.51

0.24

0.27

0.27

0.74

0.98

0.60

0.67

0.60

0.41

0.21

0.26

0.23

0.59

0.79

0.80

0.45

0.48

0.37

0.19

0.23

0.22

0.51

0.63

1.00

0.30

0.41

0.30

0.17

0.21

0.21

0.45

0.51

1.20

0.21

0.31

0.26

0.15

0.21

0.18

0.37

0.43

1.40

0.16

0.28

0.21

0.14

0.20

0.17

0.33

0.37

1.60

0.12

0.24

0.20

0.13

0.18

0.16

0.32

0.31

1.80

0.11

0.17

0.16

0.13

0.18

0.14

0.26

0.28

2.00

0.09

0.17

0.15

0.12

0.18

0.14

0.24

0.24

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table 13.3.2e Orientation sector winter exposure factor (EW) — suspended floor: climate zone 3

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.92

1.29

0.97

0.82

0.75

1.07

1.24

1.69

0.05

1.90

1.24

0.90

0.72

0.66

0.94

1.18

1.65

0.10

1.76

1.18

0.86

0.69

0.63

0.91

1.13

1.56

0.20

1.57

1.05

0.77

0.62

0.60

0.81

1.01

1.41

0.40

1.25

0.86

0.66

0.51

0.54

0.68

0.87

1.17

0.60

0.94

0.66

0.53

0.46

0.51

0.59

0.70

0.94

0.80

0.63

0.53

0.47

0.41

0.45

0.55

0.60

0.76

1.00

0.42

0.45

0.39

0.36

0.42

0.52

0.53

0.61

1.20

0.29

0.35

0.34

0.33

0.42

0.46

0.44

0.52

1.40

0.23

0.31

0.28

0.31

0.39

0.42

0.39

0.44

1.60

0.17

0.27

0.26

0.28

0.36

0.39

0.38

0.37

1.80

0.15

0.19

0.21

0.28

0.36

0.36

0.31

0.34

2.00

0.13

0.19

0.20

0.26

0.36

0.36

0.29

0.29

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table 13.3.2f Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 4

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.48

1.40

0.91

0.47

0.46

0.51

1.11

1.57

0.05

1.45

1.34

0.84

0.40

0.38

0.43

1.03

1.51

0.10

1.43

1.30

0.81

0.37

0.36

0.40

0.98

1.46

0.20

1.22

1.18

0.74

0.34

0.33

0.36

0.88

1.31

0.40

1.11

1.01

0.62

0.29

0.29

0.31

0.75

1.13

0.60

0.92

0.83

0.54

0.25

0.25

0.27

0.64

0.92

0.80

0.80

0.68

0.47

0.23

0.23

0.25

0.57

0.77

1.00

0.64

0.61

0.41

0.20

0.21

0.22

0.48

0.66

1.20

0.46

0.47

0.36

0.18

0.21

0.21

0.44

0.57

1.40

0.35

0,43

0.33

0.17

0.20

0.20

0.39

0.48

1.60

0.26

0.38

0.31

0.17

0.18

0.18

0.34

0.42

1.80

0.20

0.32

0.28

0.16

0.18

0.17

0.31

0.36

2.00

0.18

0.30

0.24

0.14

0.17

0.16

0.29

0.30

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table 13.3.2g Orientation sector winter exposure factor (EW) — suspended floor: climate zone 4

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.38

1.12

1.00

0.71

0.56

0.87

1.02

1.26

0.05

1.35

1.08

0.91

0.60

0.46

0.73

0.95

1.21

0.10

1.34

1.04

0.89

0.56

0.45

0.69

0.90

1.17

0.20

1.13

0.95

0.80

0.51

0.40

0.62

0.82

1.05

0.40

1.04

0.81

0.67

0.43

0.35

0.53

0.70

0.91

0.60

0.85

0.67

0.59

0.38

0.30

0.47

0.59

0.74

0.80

0.74

0.55

0.52

0.34

0.29

0.42

0.53

0.62

1.00

0.60

0.49

0.44

0.31

0.26

0.38

0.44

0.53

1.20

0.43

0.38

0.40

0.27

0.26

0.36

0.41

0.46

1.40

0.33

0.35

0.36

0.25

0.24

0.33

0.36

0.39

1.60

0.24

0.31

0.34

0.25

0.22

0.31

0.31

0.34

1.80

0.18

0.26

0.30

0.24

0.22

0.29

0.29

0.29

2.00

0.17

0.24

0.26

0.22

0.21

0.27

0.26

0.24

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table 13.3.2h Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 5 (lightweight wall)

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.61

1.55

1.00

0.49

0.44

0.47

1.02

1.58

0.05

1.56

1.49

0.91

0.41

0.37

0.40

0.94

1.51

0.10

1.56

1.43

0.86

0.39

0.36

0.38

0.90

1.47

0.20

1.30

1.27

0.77

0.35

0.32

0.34

0.80

1.32

0.40

1.19

1.05

0.64

0.30

0.28

0.29

0.66

1.10

0.60

0.97

0.87

0.52

0.26

0.25

0.25

0.56

0.90

0.80

0.78

0.71

0.46

0.24

0.23

0.23

0.50

0.73

1.00

0.64

0.55

0.36

0.21

0.22

0.20

0.43

0.63

1.20

0.43

0.48

0.33

0.20

0.20

0.19

0.35

0.50

1.40

0.32

0.36

0.27

0.1

Tables

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 13.3.2.

State and territory variations all clauses side by side →

Defined terms used