Table 13.3.2o Orientation sector winter exposure factor (EW) — suspended floor: climate zone 7

Part 13.3 External glazing

Open Table 13.3.2o on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth east
0.001.871.431.200.750.530.931.131.62
0.051.811.371.120.630.440.781.041.56
0.101.811.341.060.590.420.730.991.53
0.201.701.250.990.530.380.660.901.38
0.401.461.090.840.450.320.560.751.22
0.601.340.950.730.400.290.490.661.04
0.801.140.820.640.360.260.440.590.90
1.001.040.730.590.320.240.390.510.77
1.200.820.610.490.300.230.370.450.68
1.400.750.600.480.280.210.340.410.52
1.600.580.430.440.260.200.290.380.49
1.800.470.410.350.240.200.290.350.42
2.000.350.340.350.220.180.290.300.36

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.2o.