Table · ABCB Housing Provisions 2025

Table 13.3.2z Winter solar heat gain factors: climate zone 2

Part 13.3 External glazing

Open Table 13.3.2z on NCC Online ↗
Type of factorFactor for a floor in direct contact with the groundFactor for a suspended floor
Room factor (RW) for a bedroom and a room which is not a conditioned space0.401.00
Bedroom solar heat gain factor (BSW)1.801.02
Level factor (LW) for all floor levels above the lowest floor1.101.20
Frame factor (FW) for frames with a solar absorptance of ≤ 0.400.980.97
Frame factor (FW) for frames with a solar absorptance of > 0.40 to < 0.681.000.99
Frame factor (FW) for frames with a solar absorptance of ≥ 0.681.031.03
Floor factor (for tiled or vinyl covered floor) (HW)1.14Not applicable

Table Notes

Where a factor is listed as ‘Not applicable’, the value of the factor must be taken as 1.0.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.2z.

Defined terms used