Table 13.3.3d Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 2

Part 13.3 External glazing

Open Table 13.3.3d on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.591.081.500.930.401.051.781.19
0.050.490.941.350.820.330.951.641.06
0.100.450.871.280.770.310.881.520.97
0.200.390.761.130.680.280.791.330.84
0.400.320.570.900.540.220.631.100.65
0.600.270.450.740.440.180.520.890.48
0.800.240.380.620.360.160.430.770.42
1.000.210.310.530.310.130.380.630.34
1.200.190.280.430.270.120.320.550.30
1.400.170.250.390.250.120.280.480.26
1.600.160.240.340.220.100.250.410.24
1.800.140.210.300.200.090.240.370.22
2.000.140.190.270.190.090.210.360.20

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3d.