13.3.3 External glazing — summer
(1) In climate zones 1 to 7, the aggregate solar heat gain of the glazing in each storey of a building, including any mezzanine, must—
not exceed the allowance resulting from multiplying the floor area of each storey, measured within the enclosing walls, by the constant CSHGC obtained from Table 13.3.3a; and
be calculated in accordance with the following formula:
[formula] (2) In the formula at (1)(b)—
[formula] = the area of each glazing element; and
[formula] = the Total System SHGC for each glazing element not exceeding 0.7; and
[formula] = the summer exposure factor for each glazing element obtained from Table 13.3.3b, 13.3.3c, 13.3.3d, 13.3.3e, 13.3.3f, 13.3.3g, 13.3.3h, 13.3.3i, 13.3.3j, 13.3.3k, 13.3.3l, 13.3.3m, 13.3.3n, 13.3.3o, 13.3.3p or 13.3.3q; and
[formula] = the factor in Table 13.3.3r, 13.3.3s, 13.3.3t, 13.3.3u, 13.3.3v, 13.3.3w, 13.3.3x or 13.3.3y for each glazing element located in a bedroom or room which is not a conditioned space; and
[formula] = the factor in Table 13.3.3r, 13.3.3s, 13.3.3t, 13.3.3u, 13.3.3v, 13.3.3w, 13.3.3x or 13.3.3y for each glazing element located on a floor level above the lowest floor; and
[formula] = the frame factor in Table 13.3.3r, 13.3.3s, 13.3.3t, 13.3.3u, 13.3.3v, 13.3.3w, 13.3.3x or 13.3.3y for each glazing element; and
[formula] = the floor factor in Table 13.3.3r, 13.3.3s, 13.3.3t, 13.3.3u, 13.3.3v, 13.3.3w, 13.3.3x or 13.3.3y for each glazing element.
(3) For the purposes of this clause—
orientation sectors must be determined in accordance with Figure 13.3.2a; and
P/H must be measured in accordance with Figure 13.3.2b.
Table 13.3.3a Constant for solar heat gain coefficient (CSHGC): climate zones 1 to 7
Floor type
Ventilation opening area
Climate zone
1
2
3
4
5 (lightweight wall)
5 (concrete or brick wall)
6
7
Floor in direct contact with the ground
5%
0.0672
0.0595
0.0945
0.0604
0.0484
0.0657
0.0786
0.0762
10%
0.0718
0.0640
0.0985
0.0626
0.0538
0.0695
0.0817
0.0821
15%
0.0770
0.0682
0.1001
0.0641
0.0569
0.0714
0.0832
0.0871
20%
0.0827
0.0719
0.1007
0.0650
0.0587
0.0723
0.0840
0.0912
Suspended floor
5%
0.0431
0.0324
0.0768
0.0651
0.0334
0.0630
0.0963
0.0750
10%
0.0497
0.0404
0.0783
0.0697
0.0426
0.0683
0.0989
0.0778
15%
0.0541
0.0458
0.0792
0.0721
0.0477
0.0710
0.1001
0.0789
20%
0.0570
0.0494
0.0796
0.0734
0.0505
0.0723
0.1007
0.0793
Table Notes
The ventilation opening area is the total area of each ventilation opening divided by the floor area of the storey, including any mezzanine.
No window may have a design ventilation opening greater than 90% because the window frame will always obstruct some of the area of the opening.
Where the ventilation opening area is more than 20%, the CSHGC value corresponding to 20% ventilation opening area is to be used.
Where the floor construction of a storey, including any mezzanine, is partly in direct contact with the ground and partly suspended, the constant is to be—
interpolated between the constants in proportion to the floor area of each floor type; or
the constant for a suspended floor.
If the ventilation opening area is between the values shown in this Table, the constant may be interpolated.
Table 13.3.3b Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 1
P/H
North
North east
East
South east
South
South west
West
North west
0.00
1.35
1.64
1.69
1.62
1.13
1.65
1.72
1.66
0.05
1.14
1.45
1.56
1.47
0.98
1.52
1.60
1.46
0.10
1.07
1.33
1.45
1.40
0.88
1.42
1.50
1.35
0.20
0.96
1.15
1.32
1.23
0.72
1.22
1.30
1.17
0.40
0.78
0.88
1.03
0.90
0.55
0.98
1.08
0.92
0.60
0.65
0.72
0.86
0.77
0.44
0.78
0.86
0.74
0.80
0.57
0.61
0.69
0.61
0.39
0.68
0.75
0.62
1.00
0.49
0.51
0.59
0.54
0.33
0.56
0.62
0.55
1.20
0.47
0.45
0.48
0.43
0.29
0.51
0.55
0.51
1.40
0.44
0.41
0.42
0.39
0.29
0.42
0.48
0.43
1.60
0.39
0.35
0.37
0.34
0.23
0.38
0.44
0.41
1.80
0.34
0.35
0.35
0.29
0.22
0.36
0.39
0.35
2.00
0.31
0.33
0.30
0.27
0.21
0.31
0.36
0.33
Table Notes
For P/H between those in this Table, either use the next lowest P/H or interpolate.
Table 13.3.3c Orientation sector summer exposure factor (ES) — suspended floor: climate zone 1
P/H
North
North east
East
South East
South
South west
West
North west
0.00
0.61
0.96
1.43
1.19
0.70
1.15
1.32
0.92
0.05
0.51
0.84
1.32
1.08
0.61
1.06
1.23
0.81
0.10
0.48
0.78
1.23
1.03
0.55
0.99
1.15
0.75
0.20
0.43
0.67
1.12
0.90
0.45
0.85
1.00
0.65
0.40
0.35
0.51
0.88
0.66
0.34
0.68
0.83
0.51
0.60
0.29
0.42
0.73
0.57
0.28
0.54
0.66
0.41
0.80
0.26
0.35
0.59
0.45
0.24
0.47
0.58
0.35
1.00
0.22
0.30
0.50
0.39
0.20
0.39
0.48
0.30
1.20
0.21
0.26
0.41
0.32
0.18
0.35
0.42
0.28
1.40
0.20
0.24
0.36
0.29
0.18
0.29
0.37
0.24
1.60
0.18
0.21
0.31
0.25
0.15
0.26
0.34
0.23
1.80
0.15
0.21
0.30
0.21
0.14
0.25
0.30
0.20
2.00
0.14
0.19
0.26
0.20
0.13
0.22
0.28
0.18
Table Notes
For P/H between those in this Table, either use the next lowest P/H or interpolate.
Table 13.3.3d Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 2
P/H
North
North east
East
South east
South
South west
West
North west
0.00
0.59
1.08
1.50
0.93
0.40
1.05
1.78
1.19
0.05
0.49
0.94
1.35
0.82
0.33
0.95
1.64
1.06
0.10
0.45
0.87
1.28
0.77
0.31
0.88
1.52
0.97
0.20
0.39
0.76
1.13
0.68
0.28
0.79
1.33
0.84
0.40
0.32
0.57
0.90
0.54
0.22
0.63
1.10
0.65
0.60
0.27
0.45
0.74
0.44
0.18
0.52
0.89
0.48
0.80
0.24
0.38
0.62
0.36
0.16
0.43
0.77
0.42
1.00
0.21
0.31
0.53
0.31
0.13
0.38
0.63
0.34
1.20
0.19
0.28
0.43
0.27
0.12
0.32
0.55
0.30
1.40
0.17
0.25
0.39
0.25
0.12
0.28
0.48
0.26
1.60
0.16
0.24
0.34
0.22
0.10
0.25
0.41
0.24
1.80
0.14
0.21
0.30
0.20
0.09
0.24
0.37
0.22
2.00
0.14
0.19
0.27
0.19
0.09
0.21
0.36
0.20
Table Notes
For P/H between those in this Table, either use the next lowest P/H or interpolate.
Table 13.3.3e Orientation sector summer exposure factor (ES) — suspended floor: climate zone 2
P/H
North
North east
East
South east
South
South west
West
North west
0.00
0.43
0.81
1.16
0.75
0.36
1.06
1.88
1.11
0.05
0.36
0.71
1.05
0.67
0.30
0.96
1.72
0.99
0.10
0.33
0.66
0.99
0.62
0.29
0.89
1.60
0.90
0.20
0.28
0.57
0.87
0.55
0.25
0.80
1.40
0.78
0.40
0.23
0.43
0.69
0.44
0.20
0.64
1.16
0.60
0.60
0.20
0.34
0.57
0.36
0.17
0.52
0.94
0.45
0.80
0.17
0.29
0.48
0.30
0.15
0.44
0.81
0.39
1.00
0.16
0.23
0.41
0.25
0.12
0.38
0.66
0.32
1.20
0.14
0.21
0.33
0.22
0.11
0.32
0.57
0.28
1.40
0.13
0.19
0.30
0.20
0.11
0.29
0.50
0.24
1.60
0.11
0.18
0.27
0.18
0.10
0.26
0.43
0.22
1.80
0.10
0.16
0.23
0.16
0.09
0.25
0.39
0.20
2.00
0.10
0.15
0.21
0.15
0.08
0.21
0.38
0.19
Table Notes
For P/H between those in this Table, either use the next lowest P/H or interpolate.
Table 13.3.3f Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 3
P/H
North
North east
East
South east
South
South west
West
North west
0.00
0.95
1.51
1.70
1.53
0.92
1.45
1.50
1.41
0.05
0.80
1.36
1.58
1.40
0.80
1.31
1.39
1.26
0.10
0.75
1.23
1.50
1.33
0.76
1.24
1.31
1.16
0.20
0.65
1.06
1.32
1.17
0.64
1.09
1.17
1.02
0.40
0.54
0.81
1.06
0.92
0.53
0.90
0.92
0.78
0.60
0.48
0.62
0.89
0.75
0.43
0.71
0.78
0.62
0.80
0.41
0.51
0.71
0.61
0.38
0.63
0.66
0.49
1.00
0.34
0.42
0.60
0.52
0.34
0.54
0.58
0.41
1.20
0.32
0.38
0.50
0.44
0.29
0.46
0.47
0.36
1.40
0.29
0.32
0.42
0.40
0.28
0.40
0.45
0.32
1.60
0.29
0.29
0.40
0.35
0.22
0.39
0.39
0.29
1.80
0.26
0.28
0.36
0.31
0.22
0.35
0.36
0.27
2.00
0.26
0.26
0.30
0.31
0.21
0.30
0.30
0.24
Table Notes
For P/H between those in this Table, either use the next lowest P/H or interpolate.
Table 13.3.3g Orientation sector summer exposure factor (ES) — suspended floor: climate zone 3
P/H
North
North east
East
South east
South
South west
West
North west
0.00
0.78
1.30
1.56
1.36
0.79
1.16
1.09
1.11
0.05
0.66
1.18
1.45
1.24
0.68
1.05
1.01
0.99
0.10
0.62
1.06
1.38
1.17
0.65
0.99
0.95
0.91
0.20
0.53
0.91
1.21
1.04
0.55
0.87
0.85
0.80
0.40
0.45
0.70
0.97
0.82
0.46
0.72
0.67
0.62
0.60
0.39
0.54
0.81
0.67
0.37
0.57
0.57
0.48
0.80
0.34
0.44
0.65
0.54
0.32
0.50
0.48
0.39
1.00
0.28
0.36
0.55
0.46
0.29
0.43
0.42
0.32
1.20
0.27
0.33
0.46
0.39
0
Tables
- Table 13.3.3a Constant for solar heat gain coefficient (CSHGC): climate zones 1 to 7
- Table 13.3.3b Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 1
- Table 13.3.3c Orientation sector summer exposure factor (ES) — suspended floor: climate zone 1
- Table 13.3.3d Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 2
- Table 13.3.3e Orientation sector summer exposure factor (ES) — suspended floor: climate zone 2
- Table 13.3.3f Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 3
- Table 13.3.3g Orientation sector summer exposure factor (ES) — suspended floor: climate zone 3
- Table 13.3.3h Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 4
- Table 13.3.3i Orientation sector summer exposure factor (ES) — suspended floor: climate zone 4
- Table 13.3.3j Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 5 (lightweight or masonry veneer wall)
- Table 13.3.3k Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 5 (concrete or masonry wall)
- Table 13.3.3l Orientation sector summer exposure factor (ES) — suspended floor: climate zone 5 (lightweight or masonry veneer wall)
- Table 13.3.3m Orientation sector summer exposure factor (ES) — suspended floor: climate zone 5 (concrete or masonry wall)
- Table 13.3.3n Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 6
- Table 13.3.3o Orientation sector summer exposure factor (ES) — suspended floor: climate zone 6
- Table 13.3.3p Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 7
- Table 13.3.3q Orientation sector summer exposure factor (ES) — suspended floor: climate zone 7
- Table 13.3.3r Summer solar heat gain factors: climate zone 1
- Table 13.3.3s Summer solar heat gain factors: climate zone 2
- Table 13.3.3t Summer solar heat gain factors: climate zone 3
- Table 13.3.3u Summer solar heat gain factors: climate zone 4
- Table 13.3.3v Summer solar heat gain factors: climate zone 5 (lightweight or masonry veneer wall)
- Table 13.3.3w Summer solar heat gain factors: climate zone 5 (concrete or masonry wall)
- Table 13.3.3x Summer solar heat gain factors: climate zone 6
- Table 13.3.3y Summer solar heat gain factors: climate zone 7