Table · ABCB Housing Provisions 2025

Table 13.3.3f Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 3

Part 13.3 External glazing

Open Table 13.3.3f on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.951.511.701.530.921.451.501.41
0.050.801.361.581.400.801.311.391.26
0.100.751.231.501.330.761.241.311.16
0.200.651.061.321.170.641.091.171.02
0.400.540.811.060.920.530.900.920.78
0.600.480.620.890.750.430.710.780.62
0.800.410.510.710.610.380.630.660.49
1.000.340.420.600.520.340.540.580.41
1.200.320.380.500.440.290.460.470.36
1.400.290.320.420.400.280.400.450.32
1.600.290.290.400.350.220.390.390.29
1.800.260.280.360.310.220.350.360.27
2.000.260.260.300.310.210.300.300.24

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3f.