Table · ABCB Housing Provisions 2025

Table 13.3.3p Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 7

Part 13.3 External glazing

Open Table 13.3.3p on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.061.301.361.090.771.111.491.39
0.050.911.171.230.960.650.991.361.26
0.100.841.081.160.930.610.931.291.15
0.200.680.941.040.810.540.831.141.01
0.400.440.720.850.670.460.670.930.75
0.600.350.570.730.580.400.580.790.60
0.800.310.440.600.510.340.500.660.47
1.000.280.370.540.430.300.430.550.38
1.200.240.310.460.390.280.380.480.32
1.400.210.260.400.350.250.340.410.28
1.600.200.230.370.310.240.320.390.25
1.800.190.220.310.280.220.290.340.22
2.000.180.210.300.270.220.260.310.21

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3p.