Table · ABCB Housing Provisions 2025
Table 13.3.3y Summer solar heat gain factors: climate zone 7
| Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor |
|---|---|---|
| Room factor (RS) for a bedroom and a room which is not a conditioned space | 0.40 | 0.40 |
| Level factor (LS) for all other floor levels | 1.40 | 1.30 |
| Frame factor (FS) for frames with a solar absorptance of ≤ 0.40 | 0.91 | 0.85 |
| Frame factor (FS) for frames with a solar absorptance of > 0.40 to < 0.68 | 1.00 | 1.00 |
| Frame factor (FS) for frames with a solar absorptance of ≥ 0.68 | 1.00 | 1.00 |
| Floor factor (for tiled or vinyl covered floor) (HS) | 0.85 | Not applicable |
Table Notes
Where a factor is listed as ‘Not applicable’, the value of the factor must be taken as 1.0.
Table for 13.3.3 External glazing — summer
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3y.