Table · ABCB Housing Provisions 2025

Table 4.2.11a Alternative mesh/reinforcing bar sizes

Part 4.2 Footings, slabs and associated elements

Open Table 4.2.11a on NCC Online ↗
Trench mesh (TM)Area — mm2Reinforcing bar alternativeTrench mesh alternative
2-L8TM912-N10 or 1-N12Not applicable
3-L8TM1362-N10 or 2-N12Not applicable
4-L8TM1822-N122-L11TM
5-L8TM2272-N123-L11TM
2-L11TM1801-N16 or 2-N122x2-L8TM
3-L11TM2703-N122x3-L8TM
4-L11TM3602-N162x4-L8TM
2-L12TM2222-N123-L11TM
3-L12TM3333-N124-L11TM
4-L12TM4444-N125-L11TM

Table Notes

Where necessary, 2 layers of mesh may be used.

L11TM and L12TM may be replaced by RL1118 and RL1218 mesh respectively.

L11TM may be replaced by two layers of L8TM.

Table for 4.2.11 Steel reinforcement

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 4.2.11a.