4.2.11 Steel reinforcement
Part 4.2 Footings, slabs and associated elements · NCC 2019: 3.2.3.2
(1) Materials used for reinforcing steel must comply with AS 2870 and be—
welded wire reinforcing fabric; or
trench mesh; or
steel reinforcing bars.
(2) Steel reinforcing bars may be substituted for trench mesh in accordance with Table 4.2.11a.
(3) Minimum laps for reinforcement as shown in Table 4.2.11b and Figure 4.2.11a must be provided where reinforcing is used.
(4) Any slab in H1D4 with a re-entrant corner must have—
two strips of 3-L8TM; or
one strip of 3-L11TM; or
3-N12 bars,
not less than 2 m in length and placed at an angle of 45° across the corner such that the centre of the 2 m length is at the location of the internal angle of the slab in accordance with Figure 4.2.11b.
(5) Footings and slabs-on-ground must have concrete cover between the outermost edge of the reinforcement (including ligatures, tie wire etc.) and the surface of the concrete of not less than—
40 mm to unprotected ground; and
30 mm to a membrane in contact with the ground; and
20 mm to an internal surface; and
40 mm to external exposure.
(6) Reinforcement must be free of loose rust, mud, paints and oils.
(7) Reinforcement must be placed as follows:
All reinforcement must be firmly fixed in place to prevent it moving during concreting operations.
Reinforcement must be supported off the ground or the forms by bar chairs made from wire, concrete or plastic.
When using wire chairs, the minimum concrete cover (see (5)) to the uncoated portion of the chair must be obtained.
Wire chairs on soft ground or plastic membrane must be placed on flat bases.
Bar chairs must be spaced at not more than 800 mm centres for steel fabric.
Table 4.2.11a Alternative mesh/reinforcing bar sizes
Trench mesh (TM)
Area — mm2
Reinforcing bar alternative
Trench mesh alternative
2-L8TM
91
2-N10 or 1-N12
Not applicable
3-L8TM
136
2-N10 or 2-N12
Not applicable
4-L8TM
182
2-N12
2-L11TM
5-L8TM
227
2-N12
3-L11TM
2-L11TM
180
1-N16 or 2-N12
2x2-L8TM
3-L11TM
270
3-N12
2x3-L8TM
4-L11TM
360
2-N16
2x4-L8TM
2-L12TM
222
2-N12
3-L11TM
3-L12TM
333
3-N12
4-L11TM
4-L12TM
444
4-N12
5-L11TM
Table Notes
Where necessary, 2 layers of mesh may be used.
L11TM and L12TM may be replaced by RL1118 and RL1218 mesh respectively.
L11TM may be replaced by two layers of L8TM.
Table 4.2.11b Minimum lap for reinforcement
Reinforcement
Minimum splice
Minimum lap at “T” intersections
Minimum lap at “L” intersections
Steel reinforcing bars ≤12 mm diameter
500 mm
Full width across the junction
One outer bar must be bent and continue 500 mm (min) around corner
Steel reinforcing bars >12 mm to ≤16 mm diameter
700 mm
Full width across the junction
One outer bar must be bent and continue 500 mm (min) around corner
Trench mesh
500 mm
Full width across the junction
Full width across the junction
Square and rectangular mesh
The two outermost transverse wires of one sheet must overlap the two outermost transverse wires of the other
Not applicable
Not applicable
Figure 4.2.11a Splice, L and T intersections
Figure 4.2.11b Reinforcing for re-entrant corners