Table · ABCB Housing Provisions 2025
Table 8.3.3b Glass thickness for wind class not exceeding N2: monolithic annealed glass (mm)
| Edge (mm) | 300 | 450 | 600 | 750 | 900 | 1050 | 1200 | 1350 | 1500 | 1650 |
|---|---|---|---|---|---|---|---|---|---|---|
| 300 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| 450 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| 600 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 4 | 4 |
| 750 | 3 | 3 | 3 | 3 | 3 | 3 | 4 | 4 | 4 | 4 |
| 900 | 3 | 3 | 3 | 3 | 3 | 4 | 4 | 4 | 4 | 4 |
| 1050 | 3 | 3 | 3 | 3 | 4 | 4 | 4 | 4 | 4 | 4 |
| 1200 | 3 | 3 | 3 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
| 1350 | 3 | 3 | 3 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
| 1500 | 3 | 3 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
| 1650 | 3 | 3 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
| 1800 | 3 | 3 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 5 |
| 1950 | 3 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 5 | 5 |
| 2100 | 3 | 4 | 4 | 4 | 4 | 4 | 4 | 5 | 5 | 6 |
| 2250 | 3 | 4 | 4 | 4 | 4 | 4 | 5 | 5 | 5 | 6 |
| 2400 | 3 | 4 | 4 | 4 | 4 | 4 | 5 | 5 | 5 | 6 |
| 2550 | 3 | 4 | 4 | 4 | 4 | 4 | 5 | 5 | 5 | 6 |
| 2700 | 3 | 4 | 4 | 4 | 5 | 5 | 5 | 5 | 6 | 6 |
Table for 8.3.3 Fully framed glazing installed in perimeter of buildings
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 8.3.3b.