Western Australia variation · ABCB Housing Provisions 2025

WA 8.2.2 Installation of windows

WA Part 8.2 Windows and external glazed doors · varies 8.2.2 Installation of windows

Open on NCC Online ↗

Delete clause 8.2.2 and insert WA 8.2.2 as follows:

Windows must be installed in accordance with the following:

Structural building loads must not be transferred to the window assembly.

A minimum 10 mm gap must be provided between the top of the window assembly and any load bearing framing element.

The requirements of (b) may be increased where necessary to allow for frame settlement over wide openings.

Packing, if provided between each window assembly and the frame, must be—

located along each side and bottom; and

fixed to ensure the sides and bottom of the window assembly remain straight; and

clear of any flashing material.

Exemptions

8.2.2(b) does not apply to windows in a masonry wall element.

New in NCC 2025. No WA 8.2.2 in ABCB Housing Provisions 2022; it may have moved or been renumbered.

The national clause