NSW A5G6 Fire hazard properties and combustibility

NSW Part A5 Documentation of design and construction · varies A5G6 Fire hazard properties and combustibility

Open on NCC Online ↗

Delete clause A5G6 and insert NSW A5G6 as follows:

(1) Subject to (3), where a Deemed-to-Satisfy Provision requires a building material, component, or assembly to have a fire hazard property it must be determined as follows:

For critical radiant flux and smoke development rate, in accordance with AS ISO 9239.1.

For Smoke-Developed Index and Spread-of-Flame Index, in accordance with AS/NZS 1530.3.

For group number, average specific extinction area and smoke growth rate index (SMOGRARC), in accordance with AS 5637.1.

For Flammability Index, in accordance with AS 1530.2.

(2) Subject to (4) and (5), where a Deemed-to-Satisfy Provision requires a building material, component, or assembly to be non-combustible, its combustibility may be determined in accordance with AS 1530.1 or C2D10(5).

(3) A building material, component, or assembly is deemed to have a fire hazard property if—

it is identical with a prototype that has been tested in accordance with (1) and the fire hazard property achieved by the prototype is confirmed in a report that—

describes the method and conditions of the test and form of construction of the tested prototype in full; and

confirms that the application of restraint to the prototype complies with the test standard; or

it differs in only a minor degree from a prototype tested under (a) and a report—

confirms that the building product, component, or assembly can achieve the fire hazard property despite the minor departures from the tested prototype; and

describes the materials, construction, conditions of restraint and other limitations which are necessary to achieve the fire hazard property.

(4)  A building material is deemed to be non-combustible if—

it is identical with a material that has been tested in accordance with AS 1530.1 and has not been deemed combustible; or

it is deemed non-combustible in accordance with C2D10(5); or

it differs in only a minor degree to a material tested under (a) and a report—

confirms that the material can achieve the attribute of being non-combustible despite the minor departures from the tested material; and

describes any limitations which are necessary to achieve the attribute of being non-combustible.

(5) A building component or assembly is deemed to be non-combustible if it is constructed wholly of materials that are deemed to be non-combustible.