NCC 2025 Volume Three
New South Wales variations
27 NSW variations to NCC 2025 Volume Three: clauses replaced, added or deleted in New South Wales. Search with NSW variations.
- NSW A2G2 Performance SolutionDelete clause A2G2 and insert NSW A2G2 as follows: (1) A Performance Solution is achieved by demonstrating— compliance with all relevant Performance…
- NSW A5G3 Evidence of suitability ─ Volumes One and Two (BCA)Delete clause A5G3 and insert NSW A5G3 as follows: (1) Subject to A5G5, NSW A5G6, A5G7 and A5G9, evidence to support that the use of a material,…
- NSW A5G6 Fire hazard properties and combustibilityDelete clause A5G6 and insert NSW A5G6 as follows: (1) Subject to (3), where a Deemed-to-Satisfy Provision requires a building material, component,…
- NSW A6G7 Class 6 buildingsDelete clause A6G7 and insert NSW A6G7 as follows: A Class 6 building is a shop or other building for sale of goods by retail or the supply of…
- NSW B1D2 Water EfficiencyDelete clause B1D2 and insert NSW B1D2 as follows: (1) A tap or outlet used for a shower, basin, kitchen sink or laundry trough must be a minimum of…
- NSW B1D3 General requirementsDelete clause B1D3 and insert NSW B1D3 as follows: (1) A cold water service must be in accordance with AS/NZS 3500.1, with the following variations…
- NSW B1P5 Water EfficiencyDelete clause B1P5 and insert NSW B1P5 as follows: Where a cold water service is used, efficient use of drinking water must be achieved by—…
- NSW B2D2 Water heater in a heated water supply systemDelete clause B2D2 and insert NSW B2D2 as follows: In New South Wales energy efficiency is regulated under the Environmental Planning and Assessment…
- NSW B2D4 Water efficiencyDelete clause B2D4 and insert NSW B2D4 as follows: A tap or outlet used for a shower, basin, kitchen sink or laundry trough must be a minimum of 3…
- NSW B2D5 Maximum delivery temperatureDelete clause B2D5 and insert NSW B2D5 as follows: The delivery temperature of heated water at the outlet of each sanitary fixture must be— not more…
- NSW B2D6 Temperature control devicesDelete clause B2D6 and insert NSW B2D6 as follows: (1) A temperature control device used to deliver heated water in accordance with B2D5(a) must be…
- NSW B2D9 General RequirementDelete clause B2D9 and insert NSW B2D9 as follows: A heated water service must be in accordance with AS/NZS 3500.4, with the following variations:…
- NSW B2P8 Energy use and sourceDelete clause B2P8 and insert NSW B2P8 as follows: (1) A heated water service, including any associated distribution system and components, must…
- NSW B2P12 Water efficiencyDelete clause B2P12 and insert NSW B2P12 as follows: A heated water service must ensure the efficient use of drinking water by limiting water use…
- NSW B3D3 General requirementsDelete clause B3D3 and insert NSW B3D3 as follows: A non-drinking water service must be in accordance with AS/NZS 3500.1, with the following…
- NSW B3D5 Water efficiencyDelete clause B3D5 and insert NSW B3D5 as follows: (1) Cisterns or flushing devices for water closets must— Have a dual flushing mechanism; and Be a…
- NSW B3P8 Water EfficiencyDelete clause B3P8 and insert NSW B3P8 as follows: Where a non-drinking water service is used for flushing toilets or urinals, efficient use of…
- NSW B5D2 Drinking water serviceDelete clause B5D2 and insert NSW B5D2 as follows: (1) A hazard exists wherever it is possible for water or contaminants to enter a drinking water…
- NSW B5D3 Non-Drinking Water ServiceDelete clause B5D3 and insert NSW B5D3 as follows: (1) A non-drinking water service or supply may have a cross-connection to another separate…
- NSW B5D6 RainwaterDelete clause B5D6 and insert NSW B5D6 as follows: When drinking water is used to top up a rainwater tank or supplement a rainwater service through…
- NSW B5D8 Cooling tower water serviceInsert NSW clause B5D8 in clause B5D8 as follows: Water systems permanently attached to cooling towers backflow prevention shall be positioned so…
- NSW B6D4 Water EfficiencyDelete clause B6D4 and insert NSW B6D4 as follows: (1) Cisterns or flushing devices for water closets must— Have a dual flushing mechanism; and Be a…
- NSW B6P3 Water efficiencyDelete clause B6P3 and insert NSW B6P3 as follows: Where rainwater is used for flushing of toilets or urinals, efficient use of rainwater must be…
- NSW C2D4 General requirementsDelete clause C2D4 and insert NSW C2D4 as follows: A sanitary drainage system must be in accordance with AS/NZS 3500.2 with the following…
- NSW C2P7 DamageDelete clause C2P7 and insert NSW C2P7 as follows: (1) Damage to sanitary drainage systems from superimposed loads must be avoided. (2) Damage to…
- NSW Part B4 Fire-fighting water servicesIntroduction to this Part In New South Wales Fire-fighting water services are not the responsibility of the plumbing regulator. In New South Wales…
- NSW Part C3 On-site wastewater managementIntroduction to this Part This Part sets out the requirements for any part of an on-site wastewater management system from the point of connection…