Queensland variation · NCC 2025 Volume Three

QLD B1D2 Water efficiency

QLD Part B1 Cold water services · varies B1D2 Water efficiency

Open on NCC Online ↗

Delete subclause B1D2(2) and insert QLD B1D2(2) as follows:

(2) For a new Class 1 or Class 2 building, in an area serviced by a Network Utility Operator water supply, toilet cisterns must—

have a dual flushing mechanism; and

be a minimum 4 Star WELS rating discharging not more than 4.5 litres for a full flush; and

are compatible with the size of the toilet bowl to allow for proper functioning of the toilet.

For all other installations, cisterns or flushing devices for water closets must—

have a dual flushing mechanism; and

be a minimum 3 Star WELS rating discharging not more than 6 litres or 4.5 litres for a full flush.

Same wording in NCC 2022 Volume Three. See NCC 2022 Volume Three QLD B1D2.