South Australia variation · NCC 2025 Volume Three

SA B2D2 Water heater in a heated water supply system

SA Part B2 Heated water services · varies B2D2 Water heater in a heated water supply system

Open on NCC Online ↗

Delete clause B2D2 and insert SA B2D2 as follows:

(1) In a new or established Class 1 or Class 10 building, a water heater in a heated water supply system must comply with a standard made under section 66 of the Water Industry Act 2012.

(2) The requirements of (1) do not apply to the following:

Water heaters serving buildings other than Class 1 or Class 10.

Repairs to water heaters including:

Like for like replacements that are the result of manufacturer, supplier or installer warranty arrangements.

Repairs of components for an existing water heater that does not include a full replacement of a water heater.

Changed since NCC 2022. See NCC 2022 Volume Three SA B2D2, or show what changed.

Delete clause B2D2 and insert SA B2D2 as follows: (1) In an established Class 1 building connected to a reticulated gas supply or a new or established Class 1 or Class 10 building, a water heater in a heated water supply system must be one comply with a standard made under section 66 of the following types: A natural gas or LPG water heater, either instantaneous, continuous flow or storage, that has an energy rating of 5 stars or more. A natural gas or LPG boosted solar water heater, with a total tank volume of not more than 700 litres, that is eligible for any number (one or more) of STCs. An electric boosted solar water heater or electric heat pump water heater (air source or solar boosted), with a single tank, that is eligible for the minimum small-scale technology certificates shown in SA Table B2D2. A wood combustion water heater, with no additional heating mechanisms, with a total tank volume of not more than 700 litres. A wood combustion boosted solar water heater, with no additional heating mechanisms, with a total tank volume of not more than 700 litres. Water Industry Act 2012. (2) In an established Class 1 building that is not connected to a reticulated gas supply, a water heater must be one of the following types: A water heater complying with the requirements set out in (1). An electric water heater with a rated hot water delivery of no greater than 250 litres. An electric instantaneous water heater, having a water storage capacity no greater than one litre and total electrical input no greater than 15.0 kW. (3) The requirements of (1) and (2) do not apply to any of the following: Water heaters serving buildings other than Class 1. 1 or Class 10. Repairs to water heaters including: Like for like replacements that are the result of manufacturer, supplier or installer warranty arrangements. Replacement Repairs of components for an existing water heater that does not include a full replacement of a single major component of a solar or electric heat pump water heater (for example, a heat pump compressor/evaporator unit, a solar collector, or a storage tank). Secondary electric water heaters of up to 55 litres rated delivery, which do not serve a shower or bath. Temporary electric water heaters of up to 55 litres rated delivery, for a period not exceeding 60 days, pending installation of a complying water heater. An electric or gas vented (gravity fed) water heater, located in a roof space of an established Class 1 building, of no greater than 250 litres rated hot water delivery. A gas water heater installed entirely within a fully enclosed roof space, room or attached garage of an established Class 1 building, providing the water heater has an energy rating of 3 stars or more. Insert SA table (B2D2) B2D2 as follows: SA Table B2D2: Small-scale technology certificates Year Tank volume of 400 litres or more and not more than 700 litres Tank volume of more than 220 litres and less than 400 litres Tank volume of not more than 220 litres 2022 34 in zone 3* and/or 32 in zone 4 24 in zone 3 and/or 23 in zone 4 15 in zone 3 and/or 14 in zone 4 2023 30 in zone 3 and/or 28 in zone 4 21 in zone 3 and/or 20 in zone 4 13 in zone 3 and/or 12 in zone 4 2024 26 in zone 3 and/or 25 in zone 4 18 in zone 3 and/or 18 in zone 4 11 in zone 3 and/or 11 in zone 4 2025 22 in zone 3 and/or 21 in zone 4 16 in zone 3 and/or 15 in zone 4 10 in zone 3 and/or 9 in zone 4 Table Notes * Zones are defined by the Clean Energy Regulator

Removed words are struck through; added words are highlighted. Comparison of the text only.