Deemed-to-Satisfy Provision · NCC 2025 Volume Two

H1D6 Framing

Part H1 Structure · NCC 2019: 3.4.0, 3.4.2-3.4.4

Open H1D6 on NCC Online ↗
Varied in QLD. Check the variation for your state.

(1) Diagrams depicting framing members and associated terminology used to describe them are set out in Figures H1D6c, H1D6d and H1D6e, and in most cases are applicable for both steel and timber frame members.

(2) Terminology and spacing for structural steel members are set out in Tables H1D6a and H1D6b, and Figures H1D6a, H1D6b and H1D6f.

(3) Performance Requirement H1P1 is satisfied for steel framing if it is designed and constructed in accordance with one of the following:

Residential and low-rise steel framing:

Design: NASH Standard ‘Residential and Low-Rise Steel Framing’ Part 1.

Design solutions: NASH Standard ‘Residential and Low-Rise Steel Framing’ Part 2.

Steel structures: AS 4100.

Cold-formed steel structures: AS/NZS 4600.

(4) Performance Requirement H1P1 is satisfied for timber framing if it is designed and constructed in accordance with the following, as appropriate:

Design of timber structures: AS 1720.1.

Design of nailplated timber roof trusses: AS 1720.5.

Residential timber-framed construction – non-cyclonic areas: AS 1684.2 or AS 1684.4.

Residential timber-framed construction – cyclonic areas: AS 1684.3.

Installation of particleboard flooring: AS 1860.2.

(5) Performance Requirement H1P1 is satisfied for structural steel sections if they are designed and constructed in accordance with one of the following:

Steel structures: AS 4100.

Cold-formed steel structures: AS/NZS 4600.

For structural stability, strength and deflection, and subject to (6), Part 6.3 of the ABCB Housing Provisions.

For corrosion protection, clause 6.3.9 of Part 6.3 of the ABCB Housing Provisions.

(6) For the purposes of (5)(c), Part 6.3 of the ABCB Housing Provisions may only be used where—

the building is located in an area with a wind class of not more than N3; and

the first dimension of steel sections is installed vertically; and

all loads are evenly distributed (unless otherwise noted or allowed for); and

the building is one for which Appendix A of AS 1170.4 contains no specific earthquake design requirements; and

the structural steel members are not subject to snow loads; and

the structural steel members are in buildings within geometric limits set out in clause 1.2 of AS 4055.

(7) The use of structural software is subject to the following:

Structural software used in computer aided design of a building or structure, that uses design criteria based on the Deemed-to-Satisfy Provisions of Section H, including its referenced documents, for the design of steel or timber trussed roof and floor systems and framed building systems, must comply with the ABCB Protocol for Structural Software.

Structural software referred to in (a) can only be used for buildings within the following geometric limits:

The distance from ground level to the underside of eaves must not exceed 6 m.

The distance from ground level to the highest point of the roof, neglecting chimneys, must not exceed 8.5 m.

The building width including roofed verandahs, excluding eaves, must not exceed 16 m.

The building length must not exceed five times the building width.

The roof pitch must not exceed 35 degrees.

The requirements of (a) do not apply to design software for individual frame members such as electronic tables similar to those provided in—

AS 1684; or

NASH Standard – Residential and Low-Rise Steel Framing, Part 2.

Table H1D6a Effective load width for structural steel bearers and strutting beams—Single spanning rafter or joist

Design member

Member 1

Member 2

Effective load width

0.5 x Span 1

0.5 x (Span 1 + Span 2)

Table H1D6b Effective load width for structural steel bearers and strutting beams—Continuous spanning rafter or joist

Design Member

Member 1

Member 2

Member 3

Effective load width

0.4 x Span 1

0.6 x (Span 1 + Span 2)

0.5 x (Span 2) + Span 3

Table Notes

The length of Span 3 must not be more than 0.5 x Span 2.

Figure H1D6a Effective load width for structural steel bearers and strutting beams—Single spanning rafter or joist

Figure H1D6b Effective load width for structural steel bearers and strutting beams—Continuous spanning rafter or joist

Figure H1D6c Span and spacing terms

Figure H1D6d Typical roof framing members

Figure H1D6e Floor, wall, ceiling and other framing members

Figure H1D6f Steel member descriptions—abbreviations and profiles