QLD H1D6 Framing
QLD Part H1 Structure · varies H1D6 Framing
Delete subclause H1D6(4) and insert QLD H1D6(4) as follows:
(4) Performance Requirement H1P1 is satisfied for a timber frame if it is designed and constructed in accordance with the following, as appropriate:
Design of timber structures: AS 1720.1.
Design of nailplated timber roof trusses: AS 1720.5.
Residential timber-framed construction – non-cyclonic areas: AS 1684.2.
Residential timber-framed construction – cyclonic areas: AS 1684.3.
Residential timber-framed construction – non-cyclonic areas (simplified): AS 1684.4.
Installation of particleboard flooring: AS 1860.2.
Timber species: In addition to sub-clauses (a) to (f) above, timber used for structural purposes must be a species scheduled for the appropriate use in Schedules A, B or C of Book 2 of the December 2017 version of the "Queensland Government, Department of Agriculture, Fisheries and Forestry - Construction timbers in Queensland, Book 1 and Book 2: Properties and specifications for satisfactory performance of construction timbers in Queensland - Class 1 and 10 buildings (Houses, carports, garages, greenhouses and sheds)".