Performance Requirement · NCC 2025 Volume Two

H6P2 Energy usage

Part H6 Energy efficiency · NCC 2019: NSW P2.6.1(b), P2.6.2

Open H6P2 on NCC Online ↗
Varied in NT. Check the variation for your state.

(1) The energy value of a building’s domestic services must not exceed 70% of the energy value with—

a 3-star ducted heat pump, rated under the 2019 GEMS determination, heating all spaces that are provided with heating; and

a 3-star ducted heat pump, rated under the 2019 GEMS determination, cooling all spaces that are provided with cooling; and

a 5-star instantaneous gas water heater, rated under the 2017 GEMS determination, providing all domestic hot water; and

a lighting power density of 4 W/m2 serving all internal spaces that are provided with artificial lighting.

(2) Domestic services, including any associated distribution system and components must, to the degree necessary, have features that facilitate the efficient use of energy appropriate to—

the domestic service and its usage; and

the geographic location of the building; and

the location of the domestic service; and

the energy source.

Same wording in NCC 2022 Volume Two. See NCC 2022 Volume Two H6P2.

State and territory variations all clauses side by side →

Defined terms used