H6V2 Verification using a reference building
Part H6 Energy efficiency · NCC 2019: V2.6.2.2
(1) Compliance with H6P1 is verified when a proposed building—
compared to a reference building, using a calculation method other than house energy rating software, has—
in climate zone 1, a cooling load equal to or less than that of the reference building; or
in climate zone 8, a heating load equal to or less than that of the reference building; or
in climate zones 2, 3, 4, 5, 6 and 7, a heating load and a cooling load equal to or less than that of the reference building; and
complies with—
for building fabric thermal insulation, clause 13.2.2 of the ABCB Housing Provisions; and
for thermal breaks, clauses 13.2.3(7) and 13.2.5(5) of the ABCB Housing Provisions; and
for floor edge insulation, clauses 13.2.6(4), 13.2.6(6) and 13.2.6(7) of the ABCB Housing Provisions; and
for building sealing, Part 13.4 of the ABCB Housing Provisions or H6V3.
(2) The reference building must comply with the Deemed-to-Satisfy Provisions in Parts 13.2, 13.3 and 13.5 of the ABCB Housing Provisions.
(3) The heating load and cooling load for the proposed building and the reference building must be determined using the same—
calculation method; and
location specific data, including that of climate and topography appropriate to the location where the proposed building is to be constructed if the data is available, or the nearest location with similar climatic conditions in the same climate zone for which the data is available; and
impact of adjoining structures and features; and
soil conditions; and
orientation; and
floor plan, including the location and size of glazing; and
number of storeys; and
roof cladding and roof lights; and
separating walls; and
external non-glazed doors; and
intermediate floors; and
floor coverings; and
ventilation; and
function and use of the building and spaces, including zoning and hours of occupation; and
operating schedules for heating and cooling in Table H6V2a; and
cooling thermostat settings of—
for bedrooms, 24°C; and
for habitable rooms other than bedrooms—
in climate zones 1, 2, 3 and 4, 27°C; and
In climate zones 5, 6, 7 and 8, 26°C; and
heating thermostat setting of 20°C for all habitable rooms; and
occupancy in Table H6V2b, with —
heat gains due to occupants of—
75 W per person in bedrooms; and
105 W per person in habitable rooms other than bedrooms; and
occupancy schedules in Table H6V2c; and
internal heat gains—
from appliances, 450 W; and
from lighting, 4 W/m²; and
from cooking equipment, in Table H6V2b; and
using the operating schedules for lighting, cooking equipment and appliances, in Table H6V2d; and
air infiltration rate—
of 0.75 air changes per hour; or
equal to the intended building air change rate at 50 Pa, divided by 20, where—
an intended building air change rate at 50 Pa is specified; and
additional building sealing provisions to Part 13.4 of the ABCB Housing Provisions are specified; and
building sealing is verified using H6V3.
(4) The calculation method used must comply with ANSI/ASHRAE Standard 140 and be capable of assessing the heating load and cooling load by modelling—
the building fabric; and
glazing and shading; and
air infiltration and ventilation; and
the function and use of the building including zoning, hours of occupation, hours of heating and cooling availability and internal heat gains; and
relevant built-environment and topographical features; and
the sensible heat component of the cooling load and heating load.
(5) Climatic data employed in the calculation method must be based on hourly recorded values and be representative of a typical year for the proposed location.
Table H6V2a Heating and cooling schedules
Hour ending at
Habitable rooms other than bedrooms
Bedrooms
1:00
OFF
ON
2:00
OFF
ON
3:00
OFF
ON
4:00
OFF
ON
5:00
OFF
ON
6:00
OFF
ON
7:00
ON
ON
8:00
ON
ON
9:00
ON
ON
10:00
ON
OFF
11:00
ON
OFF
12:00
ON
OFF
13:00
ON
OFF
14:00
ON
OFF
15:00
ON
OFF
16:00
ON
OFF
17:00
ON
OFF
18:00
ON
OFF
19:00
ON
ON
20:00
ON
ON
21:00
ON
ON
22:00
ON
ON
23:00
ON
ON
0:00
OFF
ON
Table H6V2b Occupancy and cooking equipment loads
Floor area of habitable rooms (m²)
Occupancy (m²/occupant)
Cooking equipment load (W/m² of kitchen area)
100
41.2
36.2
125
44.3
34.7
150
47.8
28.9
175
51.7
24.8
200
55.8
25.3
225
60.0
22.5
250
64.4
20.2
275
68.9
18.4
300
73.3
16.9
325
77.5
15.6
350
81.6
14.5
375
85.4
13.5
400
89.0
12.7
Table H6V2c Occupancy schedules
Hour ending at
Weekday occupancy in habitable rooms other than bedrooms
Weekend occupancy in habitable rooms other than bedrooms
Weekday and weekend bedroom occupancy
1:00
0%
0%
100%
2:00
0%
0%
100%
3:00
0%
0%
100%
4:00
0%
0%
100%
5:00
0%
0%
100%
6:00
0%
0%
100%
7:00
30%
30%
50%
8:00
30%
30%
50%
9:00
100%
30%
50%
10:00
100%
100%
0%
11:00
50%
100%
0%
12:00
50%
100%
0%
13:00
50%
100%
0%
14:00
50%
50%
0%
15:00
50%
50%
0%
16:00
50%
50%
0%
17:00
100%
50%
0%
18:00
100%
50%
0%
19:00
100%
100%
50%
20:00
100%
100%
50%
21:00
100%
100%
50%
22:00
30%
100%
100%
23:00
30%
30%
100%
0:00
0%
0%
100%
Table H6V2d Lighting, cooking and appliance schedules
Hour ending at
Lighting
Cooking
Appliances
1:00
0%
0%
45%
2:00
0%
0%
40%
3:00
0%
0%
40%
4:00
0%
0%
40%
5:00
0%
0%
40%
6:00
0%
0%
40%
7:00
10%
5%
50%
8:00
10%
10%
70%
9:00
5%
10%
55%
10:00
0%
15%
50%
11:00
0%
15%
50%
12:00
0%
15%
50%
13:00
0%
20%
50%
14:00
0%
20%
50%
15:00
0%
20%
50%
16:00
0%
20%
50%
17:00
0%
25%
75%
18:00
20%
40%
95%
19:00
30%
80%
80%
20:00
35%
80%
70%
21:00
30%
40%
70%
22:00
25%
20%
65%
23:00
15%
10%
55%
0:00
0%
5%
55%
Tables
- Table H6V2a Heating and cooling schedules
- Table H6V2b Occupancy and cooking equipment loads
- Table H6V2c Occupancy schedules
- Table H6V2d Lighting, cooking and appliance schedules